Appendix A
A.1 Factory Reset
In the event that a reset is required, the DriveRack™ 260 offers you the option of performing a "Soft" or "Hard" reset.
The Soft Reset resets all operating parameters except user programs. The Hard Reset Procedure will reset all program-
mable information back to the factory defaults.
All Power-Up Functions require a button(s) to be pressed and held as the unit power is turned on.
DriveRack 260 Power-Up Button Functions
Factory ("Hard") Reset.
Press and hold the <STORE> button at power-up until the following message appears:
• Pressing the <PREV PAGE> button will start a Factory Reset (All User Programs will become
copies of the Factory Programs, all Utility settings will be defaulted, and all Security settings
will be defaulted).
• Pressing the <PROGRAM> button will abort the Factory Reset sequence and the unit will reset
normally.
System ("SOFT") Reset
• Press and hold the <UTILITY> button at power-up until the following message appears:
• Pressing the <PREV PAGE> button will start a System Reset (All Utility settings will be defaulted.)
• Pressing the <PROGRAM> button will abort the System Reset sequence and the unit will
reset normally.
A.2 Power Up Quick Key Options
The DriveRack™ 260 offer several "Quick Key" options for initial power up and are as follow:
Change Initial Program Number
• To change the initial power program number, Press and hold the <PROGRAM> button at
power-up until the following message appears:
Use Wheel to"Change Restart"Program Number"
• Turning the <DATA> wheel will select the program you wish to load at initial reset.
• Press the <PROGRAM> button again when the selection is complete. Normal resetting will
continue.
System Lock Out
• Press and hold <RTA> at power-up until one of the following messages appears:
System Unlocked All user input will be accepted
System Locked No user input will be accepted
• Rotating the <DATA> wheel to select either Lock, Unlock or Filter Unlocked the system.
• Pressing <PREV PAGE> will unlock the system if it were locked or it will lock the system if it were unlocked.
• If you wish to leave the system locked with the exception of being able to clear the feedback filters, follow the same
procedure on power up and then rotate the <DATA> wheel to select the feedback filter unlock feature.
• Pressing any other button will abort the System Lockout sequence and the unit will reset normally.
DriveRack™ User Manual
66
"! HARD RESET?"
"Yes <PREV PAGE>"
"No
<PROGRAM>"
"! SOFT RESET?"
"Yes <PREV PAGE>"
"No
<PROGRAM>"