Lamp replacement

• VS-50XLW50U, VS-67XLW50U
This product is equipped with the lamp to display images generated by DLP
consumable and it may lose its intensity or burn out during use. When the lamp intensity decreases, this
product detects such decrease and switches the lamp to the built-in spare lamp automatically. (This
function is called automatic lamp changer.) While the spare lamp is in use, a mark " " blinks on the
screen. (When the spare lamp burns out, a blue light blinks on the screen and "1." is displayed on the status
display on the rear terminal panel.) When the spare lamp burns out, contact your MITSUBISHI dealer for
replacement of the lamp and the adjustments for ensuring the same level of image quality as that before
lamp replacement (such as the screen frame adjustment, CSC adjustment, and gradation adjustment).
Do not attempt to replace the lamp and carry out the adjustments by yourself.
This product uses a lamp that contains mercury. Disposal of the lamp or the product with the lamp may be
regulated due to environmental considerations. For disposal or recycling information, please contact your
local authorities or Electronic Industries Alliance : www.eiae.org. (For US only)
• VS-50XLF50U, VS-50XLWF50U
VS-67XLF50U, VS-67XLWF50U
This product is equipped with the lamp to display images generated by DLP
consumable and it may lose its intensity or burn out during use. (When the lamp burns out, a blue light
blinks on the screen.) When the lamp burns out, contact your MITSUBISHI dealer for replacement of the
lamp and the adjustments for ensuring the same level of image quality as that before lamp replacement
(such as the screen frame adjustment, CSC adjustment, and gradation adjustment).
Do not attempt to replace the lamp and carry out the adjustments by yourself.
This product uses a lamp that contains mercury. Disposal of the lamp or the product with the lamp may be
regulated due to environmental considerations. For disposal or recycling information, please contact your
local authorities or Electronic Industries Alliance : www.eiae.org. (For US only)
• VS-50XL50U, VS-67XL50U
This product is equipped with a lamp to display images generated the DLP
The lamp is a consumable. It may burn out or the brightness may decrease during operation. In such
cases, replace the lamp with a new one as soon as possible.
(Blue light blinks on the screen when the lamp doesn't illuminate any more.)
You may purchase a new lamp from your authorized MITSUBISHI dealer.
Part number for the lamp used in the VS-50XL50U and VS-67XL50U is S-XL50LA
This product uses a lamp that contains mercury. Disposal of the lamp or the product with the lamp may be
regulated due to environmental considerations. For disposal or recycling information, please contact your
local authorities or Electronic Industries Alliance : www.eiae.org. (For US only)
Warning:
• Be sure to turn off the main power switch and unplug the power cord from the wall outlet before
replacing the lamp. Lamp replacement without turning off the main power may result in electric shock.
• Don't put metal or flammable object into the product. Using the product with any foreign object inside
may result in electric shock or fire. When you can't remove a foreign object that has entered the
projector, ask your MITSUBISHI dealer for removal.
• Insert the lamp firmly. When the lamp isn't installed properly, it won't illuminate. Improper
installation may result in fire.
Caution:
• The lamp gets very hot during operation. Don't replace the lamp immediately after operation because
you may get burned or injured. Before replacing the lamp, turn off the power to extinguish the lamp and
wait about one minute for the cooling fan to stop. Then turn off the main power switch, unplug the power
cord from the wall outlet, and wait at least one hour to allow the lamp to cool down enough to the touch.
• Be sure to put gloves on when replacing the lamp.
• A high-pressure mercury lamp is used as the light source of this product. The high-pressure mercury lamp can
explode or fail to illuminate permanently because of an impact, scratch, or deterioration through use. The
period of time until explosion or permanent failure to illuminate varies considerably from lamp to lamp
depending on operation conditions, etc. Therefore, the lamp may explode soon after you use it for the first time.
• Don't open the lamp replacement door for purposes other than lamp replacement. Unnecessary opening
of the door may result in a failure.
• When you open the lamp replacement door for the purpose of lamp replacement, don't touch any parts
inside that are not necessary for lamp replacement because you may get injured or a failure may occur.
• Don't open the lamp replacement door during operation. Unnecessary opening of the door may result in a failure.
• Don't remove screws other than specified. Removal of unspecified screws may result in a failure.
EN-6