SkyLink DIAL-ALERT AD-105 Guide Manual

Emergency dialer
Hide thumbs Also See for DIAL-ALERT AD-105 Guide:

Advertisement

If you would like to order Skylink's products or have
difficulty getting them to work or download information
and user manual, please :
1. visit our FAQ section at www.skylinkhome.com, or
2. email us at support@skylinkhome.com, or
3. call our toll free at 1-800-304-1187 from Monday to
Friday, 9 am to 5 pm EST.
Fax (800) 286-1320
101Z857-001
CUSTOMER SERVICE
17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3
Tel : (800) 304-1187
Fax : (800) 286-1320
OCT, 2010
Email : support@skylinkhome.com
www.skylinkhome.com
Emergency Dialer
DIAL-ALERT
MODEL: AD-105
TM
PAT. D410633
6243000B1

Advertisement

Table of Contents
loading

Summary of Contents for SkyLink DIAL-ALERT AD-105 Guide

  • Page 1 Emergency Dialer DIAL-ALERT MODEL: AD-105 If you would like to order Skylink’s products or have difficulty getting them to work or download information and user manual, please : 1. visit our FAQ section at www.skylinkhome.com, or 2. email us at support@skylinkhome.com, or 3.
  • Page 2: Table Of Contents

    SKYLINK TECHNOLOGIES INC. TABLE OF CONTENTS Your Guide to the PACKAGE CONTENTS....................4 Emergency Dialer OVERVIEW.....................5-6 INSTALLATION......................7-9 DIAL-ALERT LIGHTS AND SOUNDS.......................10 STANDARD PROGRAMMING...................11-15 -Selecting the Operation Mode................11 MODEL: AD-105 -Recording a Voice Message................12 -Message Playback..................13 -Program a Phone Number................13 -Program a sensor under sensor operating mode..........15 -Testing.......................15...
  • Page 3: Package Contents

    PACKAGE CONTENTS OVERVIEW All materials required for installation are included with this package The AD-105 emergency dialer can call multiple phone numbers during an emergency situation and it will playback prerecorded messages. There are 2 operating modes you can set up in the AD-105 dialer. 1 Dial-Alert (AD-105) 1 Telephone Line SC-001 Mode - Works with SC-001...
  • Page 4: Overview

    AD-105, otherwise, the communication between the double sided tape, to use for temporary installation while you are positioning sensors and the Dial Alert may not function properly. If you have a Skylink wireless the dialer. Once the dialer is positioned correctly, install it permanently with device or sensor that is not listed below, and uncertain whether it can work with screws.
  • Page 5 INSTALLATION INSTALLATION Speaker On/Off Switch 2. Thread the telephone line through the top The speaker must be on during pro- hole in the back of the unit and plug it into gramming and recording the voice the "LINE" jack. If you want to have an message in order to use the playback answering machine on the same line as feature.
  • Page 6: Lights And Sounds

    LIGHTS AND SOUNDS STANDARD PROGRAMMING There are a few programming steps you must perform before the dialer can Below is an explanation of the lights and sounds of the Dial-Alert operate. Please follow the instructions below to program these fields, including: LIGHTS - Selecting the Operation Mode ACPWR light on...
  • Page 7: Recording A Voice Message

    4. To start recording, press [ ] button. You now can start to record the voice Skylink recommends that the telephone or pager numbers of your relatives, message. The number will decrease and voice recording will stop when it neighbors, office/work, friends or doctor be programmed into your Dial-Alert.
  • Page 8: Program A Sensor Under Sensor Operating Mode

    STANDARD PROGRAMMING STANDARD PROGRAMMING 1. Enter the current password (factory default password is 0000), then Do not program the phone number to police or fire dept directly into your Dial-Alert press [PROG], display will show [P] meaning you are now in programming unless you have checked with your local authorities.
  • Page 9: Operations

    OPERATIONS OPERATIONS SC-001 Mode 1. To stop the call from calling a specific phone number. Since there is a redial count and regardless of whether the call is picked When the display shows “rEAdy”, that means the unit is in standby mode. up or not, it will redial based on the redial counts.
  • Page 10: Advanced Programming

    ADVANCED PROGRAMMING ADVANCED PROGRAMMING Changing Password Erase Programmed Panic Transmitters / Alarm Panels / Sensors Password is required for programming purposes. Factory default is 0000. You may erase the programmed wireless devices, panic transmitter, alarm To change the setting, follow the instructions below. panels and wireless sensors.
  • Page 11: Pick Up Pause Period

    ADVANCED PROGRAMMING ADVANCED PROGRAMMING 1. Enter the current password (factory default password is 0000), then 3. Enter [1] to disable universal dial tone meaning a proper dial tone must press [PROG], display will show [P] meaning you are now in programming be presented before dialing, or [2] to enable universal dial tone, so the mode.
  • Page 12: Connect The Dial-Alert With Your Existing Alarm System

    ADVANCED PROGRAMMING BATTERY MAINTENANCE The AD-105 Dial-Alert comes with 1 battery that at some point you may CONNECT THE DIAL-ALERT WITH YOUR EXISTING ALARM SYSTEM have to replace: You may connect your existing alarm system with the Dial-Alert so that the dialer will be triggered by your alarm system when it is activated.
  • Page 13: Additional Accessories

    ADDITIONAL ACCESSORIES ADDITIONAL ACCESSORIES Additional sensors and transmitters as well as add on accessories are available Temperature Sensor (TS-101A) to work with your Dial-Alert. - Monitors temperature of a specific area (i.e., greenhouse, horse farms, laboratory etc.) Security Control Panel (SC-001) - Activates Security Control Panel (SC-001) or - Four alarm modes (Day, Night, Away, Chime) Emergency Dialer (AD-105) when the tempera-...
  • Page 14 ADDITIONAL ACCESSORIES Audio Sensor (AS-101) - Detects alarm sound from existing security system alarm; sends signal to Dial-Alert. - Eliminates need for monitoring service. - 9V alkaline battery included Vibration Sensor (VS-101) - Activates Security Control Panel or Emergency Dialer when vibration is detected - Attach vibration sensor to valuables - 3V lithium battery included Garage Door Monitor...

Table of Contents