EMC CLARiiON AX150 Series Data Book page 93

Emc support matrix
Table of Contents

Advertisement

No.
Host System
116 HPQ Proliant: DL 585 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL580 (G5), DL585
28
(G2), DL585 (G5), ML350 (G5)
28
ML570 (G4)
117 Dell PowerEdge: 1900, 2900, 2950
118 HPQ Proliant: DL 585 (G5), DL385 (G5), DL585
(G5);
IBM xSeries: x3655 (7943), x3755 (7163)
119 IBM xSeries: x3650 (7979), x3655 (7943), x3655
(7985)
53
120 IBM xSeries x346 (8840)
121 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970;
HPQ Proliant: DL 585 (G5), DL365, DL385 (G2),
DL580 (G5), DL585 (G2), DL585 (G5);
53
IBM xSeries: x346 (8840)
, x3655 (7943), x3655
(7985)
122 HPQ Proliant DL385 (G5);
IBM xSeries x3755 (7163)
123 HPQ Proliant: DL 585 (G5), DL365, DL385 (G2),
DL580 (G5), DL585 (G5)
124 HPQ Proliant: DL 585 (G5), DL360 (G5), DL365,
DL385 (G2), DL385 (G5), DL580 (G5), DL585
28
(G2), DL585 (G5), ML350 (G5)
28
ML570 (G4)
125 Dell PowerEdge: 1950 III, 2900 III, 2950 III, 2970;
IBM xSeries x3655 (7943)
126 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850;
28
HPQ Proliant ML570 (G3)
;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries x3950/x3950E/x460 (8872, 8874)
Sun Sun Fire: V20z, V40z, X4100, X4200
127 Acer Altos R910;
Anders & Rodewyk Ariane: 420, 430, 620, 630;
Aquarius AquaServer NQ312;
BGM Elitas: SP1010, SR1010;
Compusys ProManaged: SR4850HW4,
SR6850HW4;
Digital Henge INNO: HR−4850, HR−4850T,
HR−6850, HR−6850T;
Gateway 9715;
HCL Infiniti Global Line 4700: HW, HW−2;
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R630 G5, R650, R650 G5,
T650;
MPC NetFRAME 6620;
MaxData Platinum 7200 IR: M5, M6;
Nanobay Nano: E8501T, SR4850, SR6850;
Ockam ES OS−6400;
PowerLeader: PR4850, PR6850, PT6850;
R−Style MARSHALL NP491;
Samsung: ZSS230−D, ZSS230−T;
Sun Sun Fire: X4100, X4200;
Verari Sabre 1100;
Wipro NetPower: 9426N4U, 9426N6U;
Wortmann TERRA AQUA: 8100, 8200
128 HPQ Proliant: DL360 (G5), DL365, DL380 (G5),
DL385 (G2), DL585 (G2), ML570 (G3)
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p);
IBM xSeries: x3650 (7979), x3655 (7985),
x3950/x3950E/x460 (8878, 8879);
Sun Sun Fire: V20z, V40z
03/04/2009
Microsoft Windows 2003 [x64]
Operating System
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
28
, ML370 (G5)
,
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
28
, ML370 (G5)
,
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
38
;
Microsoft Windows 2003 [x64]
Enterprise: Edition, Edition R2
Microsoft Windows 2003 [x64]
28
;
Enterprise: Edition, Edition R2
Host
Bus
Host Bus Adapter
Topology
4, 22,
PCI
Emulex LP1050−E
FC−AL,
23, 24
Express,
FC−SW
PCI−X
4,
PCI
Emulex LP1050Ex−E
FC−AL,
19, 22, 23, 24
Express,
FC−SW
PCI−X
4, 19,
PCI
Emulex LP1150−E
FC−AL,
22, 23, 26
Express,
FC−SW
PCI−X
4, 22,
PCI
Emulex LP982−E
FC−AL,
24, 29
Express,
FC−SW
PCI−X
4, 19,
PCI
Emulex LPe111−E
FC−AL,
22, 23, 26
Express,
FC−SW
PCI−X
4, 19,
PCI
Emulex LPe1150−E
FC−AL,
22, 23, 26
Express,
FC−SW
PCI−X
4, 19,
PCI
Emulex LPe1150−E
FC−AL,
22, 23, 26
Express,
FC−SW
PCI−X
PCI
HPQ
FC−AL,
Express,
A8002A/FC2142SR
FC−SW
19, 22, 23, 26
PCI−X
(LPe1150)
PCI
HPQ AD167A/FC2143
FC−AL,
19, 22, 23, 26
Express,
(LP1150)
FC−SW
PCI−X
PCI
QLogic
FC−AL,
4, 6, 7,
Express,
QLE2360−E−SP
FC−SW
PCI−X
17
4, 22,
PCI−X
Emulex LP1050−E
FC−AL,
23, 24
FC−SW
4, 19,
PCI−X
Emulex LP1150−E
FC−AL,
22, 23, 26
FC−SW
4, 19,
PCI−X
Emulex LP1150−E
FC−AL,
22, 23, 26
FC−SW
90
CLARiiON AX150
Storage
External
Array
Boot
Comments
2, 3
13
EMC
Y
See
CLARiiON
AX150
2, 3, 25
13
EMC
Y
See
CLARiiON
AX150
2, 3
13
EMC
Y
See
CLARiiON
AX150
2, 3, 32
13
EMC
Y
See
CLARiiON
AX150
2, 3, 25
13
EMC
Y
See
CLARiiON
AX150
2, 3, 25
13
EMC
Y
See
CLARiiON
AX150
2, 3
13
EMC
Y
See
CLARiiON
AX150
3, 25
EMC
Y
CLARiiON
AX150
3
EMC
Y
CLARiiON
AX150
2, 3, 25
1
EMC
Y
See
CLARiiON
AX150
2, 3
13
EMC
Y
See
CLARiiON
AX150
2, 3, 32
13
EMC
Y
See
CLARiiON
AX150
2, 3
13
EMC
Y
See
CLARiiON
AX150
CLARiiON AX150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents