EMC CLARiiON AX150 Series Data Book page 879

Emc support matrix
Table of Contents

Advertisement

No.
Host System
247 IBM xSeries: x3550 (7978), x3650
(7979), x3655 (7985), x3755
(8877), x3800/x260 (8866),
x3850/x366 (8864)
248 IBM xSeries: x3800/x260 (8866),
x3850/x366 (8864)
249 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6850, 6950
250 Dell PowerEdge: 1850, 1950 III,
2850, 2900, 2900 III, 2950, 2950
III, 2970, 6950;
IBM: eServer 326m (Model 7969),
xSeries x3655 (7985), xSeries
x3755 (8877), xSeries
x3850/x366 (8864)
251 Dell PowerEdge: 1950 III, 2900,
2900 III, 2950, 2950 III, 2970,
6950
252 IBM xSeries x3550 (7978)
253 Dell PowerEdge 1855
254 Fujitsu Siemens Primergy: RX600
S2, TX600 S2;
Hewlett Packard Proliant DL360:
(G4), (G4p)
255 Dell PowerEdge: 1750, 2600,
2650, 6650;
HPQ Proliant: BL40p, DL360
(G3), DL740, DL760 (G2), ML570
33
33
(G2)
, ML570 (G3)
;
Hewlett Packard Proliant DL360:
(G4), (G4p);
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365,
65
xSeries x3800/x260 (8865)
,
65
xSeries x3850/x366 (8863)
,
xSeries x3950/x3950E/x460
65
(8872, 8874)
, xSeries
x3950/x3950E/x460 (8878, 8879);
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun Sun Fire: V40z, X4100,
X4200
256 IBM xSeries x3950/x3950E/x460
(8878, 8879)
257 HPQ Proliant BL45p
258 IBM xSeries: x235, x365,
65
x3800/x260 (8865)
, x3850/x366
65
(8863)
, x3950/x3950E/x460
65
(8872, 8874)
,
x3950/x3950E/x460 (8878, 8879)
259 NEC Express 5800: 120Rh−2,
140Rd−4
260 Dell PowerEdge: 1750, 2600,
2650, 6650
261 HPQ Proliant BL20p (G2)
262 HPQ Proliant BL25p
03/04/2009
VMware ESX Server
Host
Operating System
Bus
VMware ESX Server:
PCI
IBM 24P0960 (QLA2340)
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Express,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
PCI−X
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI
IBM: 42C2069 (LPe11000)
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Express,
(LPe11002)
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
PCI−X
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI
QLogic QLA2340−E−SP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Express,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
PCI−X
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI
QLogic QLE2360−E−SP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Express,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
PCI−X
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI
QLogic QLE2460−E−SP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Express,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
PCI−X
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI
QLogic: QLA2460−E−SP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Express,
QLA2462−E−SP
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
PCI−X
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI−X
Dell 2342M
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI−X
Emulex LP1050Ex−E
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI−X
Emulex LP982−E
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI−X
Emulex: LP11000−E
3, 4, 5, 6, 7, 8, 9, 10
11, 12
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
IBM: 42D0405 (LP11000)
(LP11002)
QLogic: QLA2460−E−SP
QLA2462−E−SP
VMware ESX Server:
PCI−X
HPQ: Dual−port Fibre Channel Adapter for HP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Proliant BL25p/BL45p 381881−B21
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
Emulex−based BL25/30/35/45p Fibre Channel
3, 4, 6, 7, 8, 9, 10
3.0.3
Mezzanine HBA − 394588−B21
VMware ESX Server:
PCI−X
IBM 24P0960 (QLA2340)
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI−X
NEC N8190−120 (LP1050)
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
VMware ESX Server:
PCI−X
QLogic QLA2340−E−SP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
20
VMware ESX Server:
PCI−X
HPQ Dual−port Fibre Channel Adapter for HP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Proliant BL20p G2 300874−B21
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
20
VMware ESX Server:
PCI−X
HPQ Dual−port Fibre Channel Adapter for HP
3, 4, 5, 6, 7, 8, 9, 10
3.0.1
,
Proliant BL25p/BL45p 381881−B21
3, 4, 5, 6, 7, 8, 9, 10
3.0.2
,
3, 4, 6, 7, 8, 9, 10
3.0.3
Host Bus Adapter
38, 43, 63
1, 2, 11, 12
, 42C2071
1, 2, 11, 12
39, 43, 52
12, 43, 50
12, 32, 43, 59
12, 32, 49
,
12, 32, 49
38, 43
2, 11, 12, 23
2, 11, 23, 34
1, 2, 11, 12
1, 2,
, LP11002−E
;
1, 2, 11, 12
, 42D0407
1, 2, 11, 12
;
12, 32, 49
,
12, 32, 49
22, 43
,
2, 11, 23
38, 43, 63
2, 11, 35, 61
39, 43, 52
22, 43
22, 43
876
Storage
External
Topology
Array
Boot
Comments
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
13, 14
FC−AL,
EMC
Y
FC−SW
CLARiiON
AX150
CLARiiON AX150
CLARiiON AX150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents