Lightolier Lytespan Track Lighting Installation Instructions

Lightolier Lytespan Track Lighting Installation Instructions

Advertisement

Quick Links

READ AND UNDERSTAND
THESE INSTRUCTIONS
BEFORE INSTALLING
FIXTURE
INSTRUCTION
SHEET NO,
This fixture is intended
for installation
in accordance
with the National
Electrical
Code and local
regulations.
To assure
full compliance with local codes and regulations, check with your local electrical
Inspector before installation,
To
prevent electrical shock, turnoff electricity at fuse box before proceeding,
IS:6020
Retain these instructions
for maintenance
reference.
R1292
Page 1 of 4
INSTALLATION
INSTRUCTIONS
FOR BASIC LYTESPAN@TRACK LIGHTING INDIVIDUAL AND JOINER TRACK UNITS
Basic Lytespan track lighting is designed to support and energize LytespotsS which can be attached anywhere along the track. It is a 2-conductor system,
polarized and continuously grounded throughout, to be supplied by a single 120V, 60 Hz, 20 amp. branch circuit It maybe used with electrical fittings
identified for use with Basic Lytespan Track, It is not intended for use with a power cord or a convenience receptacle adaptor. It is not intended to be
pendant mounted by flexible cable. Basic Lytespan is listed by Underwriters Laboratories, Inc.
IMPORTANT SAFETY INSTRUCTIONS
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
~
READ ALL INSTRUCTIONS
"
THIS TRACK SYSTEM IS INTENDED FOR INSTALLATION
IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE AND
LOCAL OR FEDERAL CODE SPECIFICATIONS.
.
DO NOT INSTALL THIS TRACK IN WET OR DAMP LOCATIONS.
~
DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET ABOVE THE FLOOR,
o
DO NOT INSTALL ANY FIXTURE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY CURTAIN, OR SIMILAR COMBUSTIBLE
MATERIAL.
'
TO PREVENT ELECTRICAL SHOCK, TURN OFF ELECTRICITY AT FUSE BOX BEFORE INSTALLING THE TRACK OR ADDING TO
OR CHANGING THE CONFIGURATION
OF THE TRACK.
o
INSTRUCTIONS
FOR GROUNDING PER INSTRUCTION SHEET OF THE FEED-IN KIT USED MUST BE FOLLOWED, FAILURE TO DO
SO MAY RESULT IN A HAZARDOUS CONDITION.
~
USE #12 OR 14 GA. AWG SOLID WIRE ONLY (NOT STRANDED WIRE) FOR SUPPLY TO TRACK.
~
OBSERVE POLARITY, (NEUTRAL) WHITE SUPPLY LEAD TO CONTACT MARKED "NEUT" IN LIVE END.
"
DO NOT AllEMPT
TO ENERGIZE ANYTHING OTHER THAN TRACK LIGHTING FIXTURES ON THE TRACK. TO REDUCE THE RISK
OF FIRE AND ELECTRICAL SHOCK, DO NOT AllEMPT
TO CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES AND
THE LIKE TO THE TRACK.
SAVE THESE INSTRUCTIONS
1-1<51-1
TC> L I E 1?"i%iEL:;&:sWRR

Advertisement

loading

Summary of Contents for Lightolier Lytespan Track Lighting

  • Page 1 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE INSTRUCTION SHEET NO, This fixture is intended for installation in accordance with the National Electrical Code and local IS:6020 full compliance with local codes and regulations, check with your local electrical regulations. To assure Inspector before installation, prevent electrical shock, turnoff electricity at fuse box before proceeding,...
  • Page 2 A1103 and 12' track. Do not exceed 4' between clips. and 12' track. Do not exceed 4' between stems...
  • Page 3 INSTRUCTION SHEET NO. IS:6020 BASIC LYTESPAN LIGHTING TRACK (Cent’d.) A1103 R1292 Page 3 of 4 ~J:kYF;?:$T&J:kYFF:iY4 INDIVIDUAL TRACK UNIT(2), 4’OR 8’ UNIO B. STRAIGHT CONTINUOUS RUN OF TRACK UNITS Extend CENTERLINE to length of additional track(s) and fasten additional MOUNTING CLIPS required, (see instruction A-2). Do not exceed 4’...
  • Page 4 A1103...

This manual is also suitable for:

Lytespan track lighting individual track unitLytespan track lighting joiner track unit