1. Remove the Duplex Unit.
2. Slide the end of the Plate Stopper off of the post on the Frame L/H.
See the illustration (1).
3. Tilt back the Duplex Assembly Unit Vertical.

PHOTO INTERRUPTER (PL11.1.9: REAR INTERLOCK)

4. Remove the two screws that is securing the Rear Interlock Bracket
Sensor to the Frame.
5. Remove the Bracket, along with the attached Rear Interlock Switch.
6. Disconnect J2732 from the Rear Interlock Switch.
7. Press in on the locking clips and remove the Rear Interlock Switch
from the Bracket.

PHOTO INTERRUPTER (PL11.2.15: CHUTE COVER INTERLOCK)

8. Remove the Chute Upper.
9. Slide the Chute Assembly out of Duplex Unit.
10. Press in on the locking clips and remove the Cute Cover Interlock
Switch from the Support Duplex-L/H.
11. Disconnect J2733 from the Chute Cover Interlock Switch.
Rev. 0