Adjusting
a) The trimmer point 4 should not cover the stitch
hole in the throat plate. This applies especially
in the curve of the rail. (Danger of breaking the
needle.)
The edge 3 of the trimmer point should lie to
the left at the circular recess in the material
slider bed as shown in the illustration.
Turn main switch off.
Manually pull the transport carriage about half
of its length to the left. The trimmer guide roller
13 must be in a straight part of the rail.
Loosen screw 9. Set the shaft 11 in the holder 7
so that the bezel 8 can still be seen.
Tighten screw 9 until it touches surface.
With the trimmer swing-out and lever 5 at the
right rest, place the block 6 close on the
holder 7.
When tightening the screw 9 take care that the
plate 10 remains horizontal.
If the setting of the trimmer point has not been
achieved, then the whole trimmer is to be removed
after screw 9 has been loosened.
Loosen screws 12 and set plate 10 accordingly.
When inserting the trimmer again bring the block 6
to rest on the holder 7.