Duerkopp Adler 744-122 Service Instructions Manual page 16

Table of Contents

Advertisement

Then set the hook shaft 6 at its highest point
with the handwheel.
Read the difference from the dial gauge.
If the result does not agree with the given
dimension for the ellipse width, the lower shaft
3 must be loosened.
The measurement can also be made with a
feeler gauge between the hook bearer 8 and
the hook drive housing 7.
With adjustments in the direction of the axis the
ellipse dimension changes in a ratio of 1:2, that
is, when the lower shaft is slid e.g. 0.2 mm, the
ellipse width changes 0.1 mm.
Remove the throat plate. Place the needle
protector 16 to the rear.
8
9
10
11
13 14
15
Loosen the set collars 15 and pulley 13.
Slide the lower shaft 3 in the appropriate
direction until the correct dimension is attained.
Tighten set collars 15, so that the lower shaft 3
is tight. Align and tighten the pulley 13.
Loosen screw 18 and one of the screws 17. By
adjusting the hook bearer 8 bring the hook
point to a distance of between 0.05 and 0.1 mm
from the needle. (Hook point behind the needle).
Tighten screws 18 and 17 again.
Check the movement of the timing belt. If
necessary adjust the lower timing belt pulley.
12
3
16
17 18
17
8
17

Advertisement

Table of Contents
loading

Table of Contents