2.6.4 Setting with the Stroke Tongue

12
Setting the looping stroke can also be conducted with the setting block
and the stroke tongue.
Caution Risk of Injury !
Turn off main switch before adjusting.
Prerequisite for the setting of the looping stroke with the stroke tongue
is the correct setting of the needle bar height (see 2.6.3).
Turn the handwheel until the needle is in the 1st position (UT).
Attach the stroke tongue 1 and the setting block 2 as shown.
Pull the stroke tongue away.
Set the setting block tight by turning the handwheel.
Set the hook with the butt screws (see 2.6.1).
Setting block
Stroke tongue
1
2
Order no. 223 000531
Order no. 223 000536k