2.6 Thread Controller Spring

16
1
2
3
4
5
The thread controller spring 2 should have just reached its lowest
position when the needle has entered the cloth up to the eye.
Caution Risk of Injury !
Turn the main switch off.
Set the thread controller spring only with the sewing unit turned off.
Run
Turn the handwheel until the needle has entered the cloth up to the
eye.
Loosen screw 5.
With the bolt 4 turn the whole thread tension unit 3.
The thread controller spring 2 must just have reached its lowest
position.
Tighten screw 5 again.
Tension
Loosen screw 5.
Pull the thread tension unit 3 out.
Loosen screw 1.
Adjust bolt 4.
Tighten screw 1 again.
Reinsert the thread tension unit 3 again.
Tighten screw 5 again.