Carrier 24APA7 Performance Wiring Diagram
Carrier 24APA7 Performance Wiring Diagram

Carrier 24APA7 Performance Wiring Diagram

Performance series 2-stage air conditioner with puron refrigerant 2 to 5 nominal tons
Hide thumbs Also See for 24APA7 Performance:

Advertisement

24APA7
Performancet Series 2---Stage Air Conditioner
with Puronr Refrigerant
2 to 5 Nominal Tons
CS
BLU
RED
TRAN
BRN
230V
BLK
CCH
BLK
BLK
CONT
L1
208/230 1Ø
11 21
L2
POWER
23 23
SUPPLY
C C
EQUIP GND
RED/WHT
BRN/YEL
YEL/PNK
2
YEL/PNK
1
LPS
PL2
BLU/PNK
2
1
BLU/PNK
HPS
PL3
3
1
PL4
BRN
T1
4
BRN/YEL
C
3
LO
RED/WHT
2
HI
BLU
1
PL5
OPTIONAL
NON-COMMUNICATING
CONTROL
SEE NOTE #10
R C
W1
Y1 Y2
O
LEGEND
FACTORY POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
COMPONENT CONNECTION
FIELD SPLICE
JUNCTION
CAPACITOR
CAP
CB
CIRCUIT BOARD
CRANKCASE HEATER
CCH
CHS
CRANKCASE HEATER SWITCH
SYSTEM COMMUNICATION
COMM
COMP
COMPRESSOR
* MAY BE FIELD INSTALLED
NOTES:
1. Compressor furnished with inherent thermal protection.
2. To be wired in accordance with National Electric Code (N.E.C.) and local codes.
3. Outdoor unit control requires a minimum of 27 VA, 24 VAC control power.
4. Use copper conductors only. Use conductors suitable for at least 75ºC (167ºF).
5. If indoor section has a transformer with a grounded secondary, connect the grounded
side to "C".
6. If any of the original wire, as supplied, must be replaced, use the same or equivalent wire.
7. Check all electrical connections inside control box for tightness.
8. Do not attempt to operate unit until service valves have been opened.
9. In case of a communicating indoor system, USE WITH INFINITY / EVOLUTION USER
INTERFACE AS LISTED IN PRE-SALE LITERATURE.
10. In case of non-communicating indoor system disconnect factory provided wires from A, B, C,
and D terminals. Use factory provided wires to connect to Y1, R, C, and Y2 as required by
Installation Instructions. Cap or remove unused factory provided wires.
11. For Communicating Control only.

Wiring Diagram

CONNECTION DIAGRAM
BLU
RED
*SC
*SR
BRN
YEL
24V
1
2
5
CAP
F
COM
C
BLK
208V
YEL
CHS
BLK
H
VIO
BLK
BLK
YEL
YEL
YEL
YEL
BLU
L1
ODF CCH
VS
VR
L2
PWM1
BLU
BRN
YEL
VIO BLK RED
PWM2
CB
C
TIME
DEFROST
RVS
(MIN)
TIME
SEV
SR
C
LED
LED
OCT
ON
OFF
(DEFAULT)
QUIET
OAT
COMM STATUS
SHIFT
AS PROVIDED BY
MANUFACTURER
FORCED
SEE NOTE #11
DEFROST
A B C D
PL8
R C
W1
Y1 Y2
O
PL7
MODEL PLUG
* UC (WITH INFINITY/EVOLUTION ONLY)
CONNECT TO
R AND Y2 ON
CONTROL BOARD
TO INDOOR UNIT
CONT
CONTACTOR
COMP HIGH CAP SOLENOID
CS
HPS
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
LPS
* LS
LIQUID SOLENOID
THERMISTOR (OUTDOOR AIR)
OAT
OCT
THERMISTOR COIL
OFM
OUTDOOR FAN MOTOR
REVERSING VALVE SOLENOID
RVS
* SC
START CAPACITOR
SOLENOID EXPANSION VALVE
SEV
* SR
START RELAY
SYSTEM FUNCTION LIGHT
STATUS
TRAN
TRANSFORMER
UTILITY CURTAILMENT
* UC
Fig. 1 – Wiring Diagram — Model sizes 2 - - 5 tons, 208/230- -1
SCHEMATIC DIAGRAM (LADDER FORM)
L1
CCH
CONT
COMP
BRN
EQUIP
R
C
11
21
GND
S
*SR
BLU
YEL
OFM
BLK
2
YEL
1
LPS
PL2
2
1
HPS
PL3
BLU
3
PL1
SR
1
1
2
PL4
3
4
T1
OCT
4
C
3
BRN
LO
1
2
CONT
2
HI
1
BRN
3
PL5
BLK
4
5
CS
BLK
PL6
PL7
OAT
MODEL MODEL
SIZE
024
036
048
060
FLASH CODE
FAULT DEFINITION
On, No Flash
Standby
Low Stage
1, Pause
2, Pause
High Stage
ODU Fan Delay Defeat Not Active
3, Pause
4, Pause
ODU Fan Delay Defeat Active
Brown out is Disabled
5, Pause
6, Pause
Brown out is Active
System Communications Failure
16
25
Invalid Model Plug
High Pressure Switch Trip
31
32
Low Pressure Switch Trip
Control Fault
45
46
Brown out (230V)
Short flashes indicate the first digit in the status code, followed by long flashes indicating the second digit of
the status code.

UNIT OPERATION

This control board contains a five minute short cycle protector. A five minute delay will
occur between compressor OFF/ON cycles. To bypass delay, short forced defrost pins
for 1 second then release.
The crankcase heater is energized during off cycle below 65ºF.
CHS
TRAN 230V
C
230V
R
CAP
C
F
S
COMP
C
H
1
2
OFM
*SC
5
YEL
VS
VR
L2
L1
ODF
CCH
PWM1
BLU
BRN
YEL
VIO BLK RED
PWM2
CB
BLU
PL1
C
TIME
DEFROST
RVS
(MIN)
TIME
SEV
C
LED
LED
ON
OCT
OFF
(DEFAULT)
QUIET
SHIFT
OAT
COMM STATUS
AS PROVIDED BY
MANUFACTURER
FORCED
SEE NOTE #11
DEFROST
PL8
A B C D
R C
W1
Y1 Y2
O
MODEL PLUG
TO INDOOR UNIT
COMPONENT ARRANGEMENT
MODEL PLUG CHART
CONTROL
PIN RESISTANCE (K
)
BOARD
PLUG
1 - 4 (R1)
2 - 3 (R2)
HK70EZ
TRANSFORMER
040
18
75
042
18
120
044
18
180
CAPACITOR
046
18
270
FLASH CODE
FAULT DEFINITION
No 230v with Call to Run
47
53
Outdoor Air Temp Sensor
Coil Temp Sensor
55
56
Temp Sensor Range Error
Low Stage Thermal Cutout
71
72
High Stage Thermal Cutout
Contactor Shorted
73
74
Contactor Open (No 230v to Comp)
Low Stage Thermal Lockout (4 HRS)
81
82
High Stage Thermal Lockout (4 HRS)
Low Pressure Lockout (4 HRS)
83
84
High Pressure Lockout (4 HRS)
337894-101 REV. B
L2
CONT
23
23
1
2
3
4
OCT
1
2
3
OAT
4
5
PL6
CONTACTOR

Advertisement

loading

Summary of Contents for Carrier 24APA7 Performance

  • Page 1: Wiring Diagram

    24APA7 Performancet Series 2---Stage Air Conditioner with Puronr Refrigerant 2 to 5 Nominal Tons Wiring Diagram SCHEMATIC DIAGRAM (LADDER FORM) CONNECTION DIAGRAM TRAN 230V 230V CONT TRAN CONT COMP EQUIP COMP 230V 208V CONT 208/230 1Ø 11 21 POWER 23 23 SUPPLY EQUIP GND RED/WHT...
  • Page 2 Catalog No: 24APA7---2W Printed in U.S.A. Edition Date: 06/11 Copyright 2011 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Replaces: 24APA7--- 1W Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.