Site Requirements - Baxi Combi 105e Installation And Servicing Instructions

Gas fired wall mounted combination boiler
Table of Contents

Advertisement

5mm Min
Fig. 7
450mm Min
For Servicing
Purposes
5mm Min
In Operation
Fig. 8
450mm
5mm Min
200mm Min
780mm
200mm Min

7.0 Site Requirements

7.1
Information
1. The installation must be carried out by a CORGI
Registered Installer or other registered competent
person and be in accordance with the relevant
requirements of the current G
and Use) R
, the B
EGULATIONS
(Scotland)(Consolidation), the L
R
, the current I.E.E. W
EGULATIONS
and the bye laws of the L
OCAL
Where no specific instruction is given reference
should be made to the relevant BRITISH
STANDARD CODES OF PRACTICE. For Ireland
install in accordance with IS 813 "I
G
A
".
AS
PPLIANCES
7.2
B.S. Codes of Practice
Standard
Scope
BS 6891
Gas Installation.
BS 5546
Installation of hot water supplies for
domestic purposes.
BS 5449 Part 1
Forced circulation hot water systems.
BS 6798
Installation of gas fired hot water boilers.
BS 5440 Part 1
Flues.
BS 5440 Part 2
Ventilation.
BS 7074
Expansion vessels and ancillary
equipment for sealed water systems.
BS 7593
Treatment of water in domestic hot water
central heating systems.
WARNING - The addition of anything that may
interfere with the normal operation of the
appliance without the express written permission
of Baxi UK Limited could invalidate the appliance
warranty and infringe the G
and Use) R
.
EGULATIONS
7.3
Clearances (Figs. 7 & 8)
1. A flat vertical area is required for the installation
of the boiler.
2. These dimensions include the necessary
clearances around the boiler for case removal,
spanner access and air movement. Additional
clearances may be required for the passage of
pipes around local obstructions such as joists
running parallel to the front face of the boiler.
7.4
Location
1. The boiler may be fitted to any suitable wall with the
flue passing through an outside wall or roof and
discharging to atmosphere in a position permitting
satisfactory removal of combustion products and
providing an adequate air supply. The boiler should be
fitted within the building unless otherwise protected by
a suitable enclosure i.e. garage or outhouse. (The
boiler may be fitted inside a cupboard-see Section 7.5).
2. If the boiler is sited in an unheated enclosure then it
is recommended to leave the ON/OFF Selector Switch
in the domestic hot water and central heating position
to give frost protection.
3. If the boiler is fitted in a room containing a bath or
shower reference must be made to the current I.E.E.
W
R
and B
IRING
EGULATIONS
UILDING
boiler is to be fitted into a building of timber frame
construction then reference must be made to the
current edition of Institute of Gas Engineers Publication
IGE/UP/7 (Gas Installations in Timber Framed
Housing).
S
(Installation
AS
AFETY
R
UILDING
EGULATIONS
B
OCAL
UILDING
R
IRING
EGULATIONS
W
U
.
ATER
NDERTAKING
NSTALLATION OF
S
(Installation
AS
AFETY
R
. If the
EGULATIONS
13