6.0 System Details

6.1
Information
1. The Baxi Combi 80e and 105e Combination Boilers
are 'Water Byelaws Scheme - Approved Products'.
To comply with the Water Byelaws your attention is
drawn to the following installation requirements and
notes (IRN).
a) IRN 001 -
See text of entry for installation
requirements and notes.
b) IRN 302 -
Byelaw 14.
2. Reference to the WRc publications, 'Water fittings
and materials directory' and 'Water supply byelaws
guide' give full details of byelaws and the IRNs.
6.2
Central Heating Circuit
1. The appliance is suitable for fully pumped SEALED
SYSTEMS ONLY.
Treatment of Water Circulating Systems
All recirculatory water systems will be subject to
corrosion unless an appropriate water treatment is
applied. This means that the efficiency of the system
will deteriorate as corrosion sludge accumulates
within the system, risking damage to pump and
valves, boiler noise and circulation problems.
For optimum performance after installation this
boiler and its associated central heating system must
be flushed in accordance with the guidelines given in
BS 7593 "Treatment of water in domestic hot water
central heating systems".
This must involve the use of a proprietary cleanser,
such as BetzDearborn Sentinel X300 or X400, or
Fernox Superfloc. Full instructions are supplied with
the products, but for immediate information please
contact BetzDearborn (0151 420 9563) or Fernox
(01799 550 811) directly.
For long term protection against corrosion and
scale, after flushing it is recommended that an
inhibitor such as BetzDearborn Sentinel X100, or
Fernox MB-1 or Copal is dosed in accordance with
the guidelines given in BS 7593.
Failure to flush and add inhibitor to the system
may invalidate the appliance warranty.
It is important to check the inhibitor concentration
after installation, system modification and at every
service in accordance with the manufacturer's
instructions. (Test kits are available from inhibitor
stockists.)
For information or advice regarding any of the
above contact the Baxi Helpline.
6.3
Bypass
1. The boiler is fitted with an automatic integral
bypass.
6.4
System Control
1. The boiler is designed for use in a heating
system that incorporates external controls, i.e. a
minimum of a timer device.
2. Suitable timer kits are available as optional
extras.
3. For optimum operating conditions and maximum
economy the fitting of a programmable room
thermostat, such as the Baxi Combi Controller, is
recommended.

Hide quick links: