Specifications; Gas Controls; Blower Data - Bryant 311AAV Manual

4-way multipoise induced combustion gas furnace sizes 045 thru 155 series a
Table of Contents

Advertisement

UNIT SIZE
RATINGS AND PERFORMANCE
Input Btuh *
311JAV Upflow; all 311AAV
Nonweatherized ICS
311JAVDownflow/Horizontal
Output Capacity (Btuh)
311JAV Upflow; all 311AAV
Nonweatherized ICS
311JAVDownflow/Horizontal
AFUE
Certified Temperature Rise Range
Certified External Static Pressure
Airflow CFM
ELECTRICAL
Unit Volts-Hertz-Phase
Operating Voltage Range
Maximum Unit Amps
Maximum Wire Length (Measured 1 Way in Ft)
Minimum Wire Size
Maximum Fuse or Ckt Bkr Size (Amps)**
Transformer (24v)
External Control
Power Available
Air Conditioning Blower Relay
CONTROLS
Limit Control
Heating Blower Control
Burners (Monoport)
Gas Connection Size

GAS CONTROLS

Min Inlet Pressure (In. wc)
Gas Valve (Redundant)
Max Inlet Pressure (In. wc)
Ignition Device

BLOWER DATA

Direct-Drive Motor HP (PSC)
Motor Full Load Amps
RPM (Nominal)-Speeds
Blower Wheel Diameter x Width (In.)
* Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National
Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level.
** Time-delay type is recommended.
Capacity in accordance with U.S. Government DOE test procedures.
Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter
is required for each return-air supply. An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter.
ICS-Isolated Combustion System
N/A-Not Applicable
024045
44,000
42,000
35,000
34,000
80.0
o
F
30-60
Heat/Cool
0.10/0.50
Heating
920
Cooling
845
Min-Max
5.6
47
Heating
Cooling
2
1/5
2.9
1075-3
10 x 6

SPECIFICATIONS

036045
024070
44,000
66,000
63,000
42,000
36,000
53,000
34,000
51,000
80.0
80.0
20-50
40-70
0.10/0.50
0.12/0.50
1250
720
1160
900
7.0
5.0
39
52
Solid-State Time Operation
2
3
4.5 (Natural Gas)
13.6 (Natural Gas)
1/3
1/5
5.2
2.9
1075-4
1075-4
10 x 6
10 x 6
-4-
036070
048070
66,000
66,000
63,000
63,000
54,000
53,000
51,000
51,000
80.0
80.0
30-60
25-55
0.12/0.50
0.12/0.50
1195
1450
1200
1530
115-60-1
104-127
6.7
9.4
40
29
14
15
40va
12va
35va
Standard
SPST
3
3
1/2-in. NPT
White Rodgers
Hot Surface
1/3
1/2
5.2
5.2
1075-4
1075-4
10 x 6
11 x 8
042090
048090
88,000
88,000
84,000
84,000
71,000
71,000
68,000
68,000
80.0
80.0
40-70
30-60
0.15/0.50
0.15/0.50
1375
1505
1385
1720
8.1
9.8
34
28
4
4
1/3
1/2
5.2
7.9
1075-4
1075-4
10 x 8
10 x 10