Canon NP6085 Service Manual page 355

Table of Contents

Advertisement

4. MECHANICAL SYSTEM
5) Remove the two mounting screws e, and
remove the two multi shutter stopper plates r.
6) Remove the mounting screw t, and remove
the tensioner y.
7) Remove the stop ring u, and remove the tim-
ing belt i; then, remove the pick-up/feeding
roller o.
3
9
7
4
3
Figure 4-308
4. Removing the Separation Roller
1) Remove the multifeeder assembly.
2) Remove the multifeeder cover.
3) Remove the two mounting screws, and remove
the upper left cover.
4) Remove the spring q at the front, and remove
it from the releasing lever w.
q
Figure 4-309
4-34
COPYRIGHT © 1996 CANON INC.
4
6
5
8
w
5) Turn over the multifeeder assembly, and lift the
separation roller locking plate e to remove the
separation roller r.
5. Adjusting the Pick-Up/Feeding Roller Pressure
1) If pick-up failure or double feeding occurs fre-
quently, remove the multifeeder assembly and
change the position of the spring.
q If pick-up failure occurs, increase the sepa-
ration pressure.
w If double feeding occurs, decrease the sep-
aration pressure.
Figure 4-310a
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)