Configuring The Controller; Viewing The Configuration; Using The Boot Menu Program; Configuring The Ethernet Controllers - IBM 8840 - eServer xSeries 346 User Manual

User guide
Hide thumbs Also See for 8840 - eServer xSeries 346:
Table of Contents

Advertisement

configuration method described in the instructions that come with that adapter to
view or change SCSI settings for attached devices.
See the documentation on the ServeRAID-7e (Adaptec HostRAID) Support CD for
additional information about how to use the SCSI HostRAID feature.

Configuring the controller

Complete the following steps to use the SCSI HostRAID feature to configure a
RAID level-10 array:
Note: You must have at least four hard disk drives installed in the server to
10. Restart the server.

Viewing the configuration

You can use the SCSISelect Utility program to view information about the SCSI
controller. From the list of available arrays, select an array and press Enter. Press
Esc to exit the utility.

Using the Boot Menu program

The Boot Menu program is a built-in, menu-driven configuration utility program that
you can use to temporarily redefine the first startup device without changing
settings in the Configuration/Setup Utility program.
Complete the following steps to use the Boot Menu program:
1. Turn off the server.
2. Restart the server.
3. Press F12.
4. Select the startup device.
The server returns to the startup sequence that is set in the Configuration/Setup
Utility program the next time the server starts or after the temporary settings expire.

Configuring the Ethernet controllers

The Ethernet controllers are integrated on the system board. They provide an
interface for connecting to a 10-Mbps, 100-Mbps, or 1-Gbps network and provide
full-duplex (FDX) capability, which enables simultaneous transmission and reception
of data on the network. If the Ethernet ports in the server support auto-negotiation,
the controllers detect the data-transfer rate (10BASE-T, 100BASE-TX, or
22
IBM xSeries 346 Type 8840: User's Guide
configure a RAID level-10 array.
1. From the SCSISelect Utility main menu, select Configure/View HostRAID
Settings.
2. From the list of ready drives, type C to create an array.
3. Select RAID-10 when asked to select the RAID type.
4. From the list of ready drives, select the two drives that you want to group into
the array.
5. Select Stripe Size.
6. Type an identifier for the array.
7. Select Yes if the array is bootable.
8. Select Yes to create the array.
9. Press Esc to exit the utility.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 346Eserver xseries 346 type 8840

Table of Contents