Bradford White EVERHOT TG-150E-N(X Installation And Operation Instruction Manual page 14

Everhot tankless gas water heater
Table of Contents

Advertisement

Ref
A
B
C
D
E
F
G
H
I
J
K
L
M
♦ A vent shall not terminate directly above a sidewalk or paved driveway that is located between two
single family dwelling and serves both dwellings.
▲ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the
floor.
* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance
with local installation codes and the requirements of the gas supplier.
Table 4. Installation Clearances.
Description
Clearance above grade, veranda,
porch, deck, or balcony
Clearance to window or door that
may be opened
Clearance to permanently closed
window
Vertical clearance to ventilated
soffit, located above the terminal
within a horizontal distance of 2
feet (61 cm) from the center line of
the terminal
Clearance to unventilated soffit
Clearance to outside corner
Clearance to inside corner
Clearance to each side of center
line extended above
meter/regulator assembly
Clearance to service regulator vent
outlet
Clearance to non-mechanical air
supply inlet to building or the
combustion air inlet to any other
appliance
Clearance to a mechanical air
supply inlet
Clearance above paved sidewalk
or paved driveway located on
public property
Clearance under veranda, porch,
deck, or balcony
Canadian
Installations
12 inches
(30 cm)
36 inches
(91 cm)
*
*
*
*
*
3 feet (91 cm)
within a height
15 feet (4.5 m)
above the
meter/regulator
assembly
36 inches
(91 cm)
36 inches
(91 cm)
6 feet (1.83 m)
7 feet
(2.13 m) ♦
12 inches
(30 cm) ▲
14
US
Installations
12 inches
(30 cm)
12 inches
(30 cm)
*
*
*
*
*
*
*
12 inches
(30 cm)
3 feet (91
cm) above if
within 10 feet
(3 m)
horizontally
*
*