Bosch DINION XF LTC 0495 Installation Manual page 24

15-bit digital day/night camera dinion xf ltc 0620/0495 series;
Hide thumbs Also See for DINION XF LTC 0495:
Table of Contents

Advertisement

Dinion
| Installation Manual
XF
Install I/O --> Alarm submenu
Function
Selection
ACTIVE
NONE, HIGH,
LOW
ACTION
NONE, MONO,
MODE1, MODE2,
MODE3
ALARM
VMD, REMOTE,
OUT
DAY/NIGHT,
FILTER MOVE
EXIT
Install sync submenu
Function
Selection
SYNC
INTERNAL, LINE
LOCK, HV
LOCK,
GENLOCK
DETECTED
SYNC
VPHASE
0, 2, ... 358
HPHASE
-25, ..., 0, ...
+125
SUB
0, 2, ... 358
PHASE
EXIT
Note
VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no
valid locking signal.
Bosch Security Systems | 2004-01 | V1.0
Description
Selects active_HIGH or active_LOW for the alarm
input connector. Select NONE to disable alarm
switching.
Selects the operating mode of the camera upon
switching the alarm input.
• Select VMD to close the output relay upon VMD
alarms.
• Select REMOTE to make the output relay available
to remote communication devices.
• Day/night: the alarm output relay closes if the
camera operates in monochrome mode.
• Filter move: the alarm output relay closes before the
filter starts moving (in either direction) and opens
when the video level has stabilized (2 - 3 seconds).
Return to the I/O menu
Description
Select INTERNAL for free running camera operation,
select LINE LOCK to lock to the power supply
frequency, select HV LOCK to lock to the signal
supplied to the external sync input, select
GENLOCK to lock the subcarrier as well.
Shows the actual sync mode used by the camera.
Adjusts the vertical phase offset (when in LINE
LOCK mode and a valid power supply frequency is
detected).
Adjust the horizontal phase offset (when in EXT lock
mode and a valid input signal is detected)
Adjusts the sub-carrier phase offset (when in EXT
LOCK mode and a valid sub-carrier is detected).
Return to the INSTALL menu