POST Error Code
179 Boot Integrity Services Segment Error
184 Asset Control Antenna not detected
186 Security Hardware Control Logic Error
190 System Security: Invalid Remote Change Requested
191 System Security: Embedded Security hardware Reset
192 System Security: Embedded Security hardware
tamper detected
193 System Security: Embedded Security hardware
Removed
194 System Security: Asset ID Antenna has been
Removed
195 System Security: Asset ID Antenna has been installed
196 System Tampered Cleared
201 Memory error
210 Keyboard stuck key error
211 Keyboard error
212 Keyboard controller error
250 Battery is dead
270 Real time clock error
271 Date and time out of range
662 Configuration Change has occurred
1762 Configuration Change has occurred
1800 PCI/PnP Error! No Hardware Interrupt Available
FRU/Action
1. Perform a flash update to update the BIOS level
2. System board
1. Make sure Asset Care and ™Asset ID are enabled
in Setup
2. RFID Antenna
3. Replace system board
If problem persists, replace the system board
If problem persists, replace the system board
If problem persists, replace the system board
If problem persists, replace the system board
If problem persists, replace the system board
If problem persists, replace the system board
If problem persists, replace the system board
If problem persists, replace the system board
1. Run Enhanced Diagnostics Memory Test
2. Memory module
3. System board
1. Check for stuck keys
2. Replace the keyboard
1. Make sure keyboard is connected correctly
2. Check for stuck keys
3. Replace the keyboard
1. Replace the keyboard
2. If problem persists, replace the system board
1. Replace the battery and run Setup
2. If problem persists, replace the system board
1. Run Setup and set date and time
2. If problem persists, replace the system board
1. Run Setup and set date and time
2. If problem persists, replace the system board
Diskette drive configuration error or wrong diskette drive
type; run Setup.
1. Run Setup and verify hard disk drive settings.
2. Run hard disk drive diagnostics.
3. Replace hard disk drive
1. Run Setup and verify PCI/ISA configuration settings.
2. Run diagnostics.
3. Replace PCI Adapter