22
EUROLIGHT LC2412 User Manual
9.3.2 Sub D connections (Analog Control)
The following table shows the cable layout of the individual contacts of the sub D
connection for analog dimmer control.
Pin No.
Cons. channel
Pin 1
Channel 1
Pin 2
Channel 2
Pin 3
Channel 3
Pin 4
Channel 4
Pin 5
Channel 5
Pin 6
Channel 6
Pin 7
Channel 7
Pin 8
Channel 8
Pin 9
Channel 9
Pin 10
Channel 10
Pin 11
Channel 11
Pin 12
Channel 12
Pin 13
Special 1
Pin 14
Special 2
Pin 15
Ground
Table. 9.1: Cable layout of the sub D connection
9.3.3 MIDI connection
Coonect to other MIDI equipment or another EUROLIGHT LC2412 by using
common MIDI cables. The cables should never be longer than 15 m (45 ft).

9.3.4 Audio connections

To control the EUROLIGHT LC2412 via an audio signal, please use a mono jack
connector with standard configuration.
Unbalanced ¼" TS connector
strain relief clamp
sleeve
tip
sleeve
(ground/shield)
tip
(signal)
Fig. 9.2: 1/4" TS connector for audio signals
9.3.5 Footswitch
You can use a footswitch to trigger chase steps. This way, both of your hands
remain free, letting you control additional settings of your LC2412.
¼" TS footswitch connector
strain relief clamp
sleeve
tip
sleeve
pole 1/ground
tip
pole 2
The footswitch connects both poles momentarily
Fig. 9.3: Footswitch connector
As long as a footswitch is kept pressed, the connection of both contacts is closed.
Therefore, a footswitch does not act as a switch.

9.4 Rack mounting

Your EUROLIGHT LC2412 is factory-equipped with rack-mounting brackets.
You can screw these on to the side of your LC2412 on a per-need basis.
Always make sure that your LC2412 is provided with sufficient
ventilation to avoid overheating of the unit!