Voltage Selector Switch

The power available to each receptacle depends on the position of the
voltage selector switch.
Switch
Position
120V ONLY
120V/240V
120V ONLY Position
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown in the table above and the total load does not exceed the
total current available.
Total Current Available:
30.0 A
(EM4000SX)
37.5 A
(EM5000SX)
45.8 A
(EM6500SX)
Receptacle
EM4000SX
1
30A at 120V
2
20A at 120V
3
20A at 120V
4A
20A at 120V
4B
1
15.0A at 120V
2
15.0A at 120V
3
15.0A at 120V
4A-4B
15.0A at 240V
Available Power
EM5000SX
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
18.8A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 240V
OPERATION
EM6500SX
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
22.9A at 120V
20A at 120V
20A at 120V
22.9A at 240V
None