Auto-throttle
system
With the switch in the AUTO position, engine speed is automatically
reduced
when ALL loads areturned OFF or disconnected. When appliances areturned
ON or reconnected, the engine returnsto rated speed. In the OFF position, the
auto-throttle
system does not operate.
The auto-throttle
system will not respond to electrical loads of less than 1
ampere. Turn the auto-throttle to the OFF position to operate loads of less than
1 amp.
Appliances with large start-up power demands may not allow the engine to
reach normal operating rpm when they are connected to the generator. Turn
the auto-throttle
to the OFF position and connect the appliance
to the
generator. If the engine still will not reach normal operating speed, check that
the appliance
does not exceed the rated load capacity of the generator/
welder.
To avoid extended warm-up periods, keep the switch OFF until the engine
reaches operating temperature.
The auto-throttle
system is not effective for use with appliances that require
only momentary power. If the tool or appliance will be turned ON and OFF
quickly, the auto -throttle switch should be in the OFF position.