SWING OPERATION

Begin air conditioner operation before performing this procedure.
To select SWING Operation
Press the SWING button (Fig. 6
The SWING Display (Fig. 7
Each time the SWING button is pressed, the swing operation will change in the
following order.
Up/down swing operation
Swing operation stops
To stop SWING Operation
Press the SWING button and select STOP.
Airflow direction will return to the setting before swing was begun.
About Swing Operation
G Up/down swing: Swing operation begins using the
following range according to the current airflow direc-
tion.
Airflow direction is 1–5 (for cooling, dry).
With the upper airflow-direction louver in the
horizontal position, the lower airflow-direction
louver moves (swings) to direct airflow to a wide
area.
Airflow direction is 3–7 (for heating).
With the airflow-direction louvers set for down-
ward or straight down airflow, airflow is directly
mainly at the floor.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and
restrain the breed of bacterium.
The COIL DRY Operation will operate for 90 minutes after pressing the COIL DRY button and it will stop automatically.
To select COIL DRY Operation
Press the COIL DRY button (Fig. 6
it stops.
The COIL DRY Indicator lamp (yellow) will light.(Then OPERATION Indicator lamp
doesn't light.)
The COIL DRY Display (Fig. 7
To cancel COIL DRY Operation
Press the START/STOP button (Fig. 6
Operation.
When the COIL DRY Display
Light up: Press the START/STOP button once
Light off: Press the START/STOP button twice.
The COIL DRY Indicator lamp (yellow) (Fig.3
Then the operation stops.
About COIL DRY Operation
G Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera-
tion can be reset.
G The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it
has no sterilization effect either.
11
).
) will light.
Left/right swing operation
Up/down/left/right swing operation
) during operation or when
) will light. Then it will disappear after 10 seconds.
) during COIL DRY
) will go out.
G Left/right swing: The airflow-direction louvers move
(swing) in the left/right airflow direction.
G Up/down/left/right swing: The airflow-direction louvers
move (swing) in both the up/down and left/right airflow
directions.
G The SWING operation may stop temporarily when the
air conditioner's fan is not operating, or when operating
at very low speeds.
G If the SET button(Vertical) is pressed during the up/
down swing operation, the up/down swing operation
will stop and if the SET button(Horizontal) is pressed
during the left/right swing operation, the left/right
swing operation will stop.