MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting 555-661-140
Error Logs
Table 2–2. Error Codes (Continued)
Error
Codes
Description
If this error occurs four times
consecutively, and if Automatic
Maintenance-Busy is enabled and the
50% maintenance-busy limit has not
been exceeded, the trunk is
busied-out automatically.
Communication problems between
the processor and the module. The
module received an unrecognized
message from the processor.
The module that occupies the
indicated slot does not match the slot
information contained in the PC or
PCMCIA card backup file.
Write to the memory card is not
succeeding or is too slow.
Erasure of the memory card is not
succeeding or is too slow.
The memory card voltage is incorrect.
Action
Turn power off for at least 1 second and
then turn it on. Repeat system
programming procedure. If problem
persists, replace the module.
Turn the processor off and then on.
Repeat system programming procedure.
If the problem persists, replace the
module.
Troubleshoot the slot descriptions in your
backup file against the actual system
modules that occupy those slots. After the
mismatch is corrected, repeat the restore
operation.
Reset the card and try again. If the
problem persists, replace the card and try
again. If the problem still persists, replace
the processor.
Reset the card and try again. If the
problem persists, replace the card and try
again. If the problem still persists, replace
the processor.
Reset the card and try again. If the
problem persists, replace the card and try
again. If the problem still persists, replace
the processor.
Continued on next page
Issue 1
August 1998
Page 2-24