Gigabyte GA-P55A-UD3 User Manual page 102

Lga1156 socket motherboard
Table of Contents

Advertisement

For the Marvell 9128:
Turn off your computer and replace the failed hard drive with a new one. Please note to perform the rebuild,
you must enter the GSATA RAID Configuration menu in BIOS Setup.
Step 1:
After the system starts, enter the BIOS Setup program and go to Integrated Peripherals. Press <Enter> on
GSATA RAID Configuration to access the RAID configuration menu. Move the selection bar to the array to
be rebuilt (for example, VD 0: New_VD) and press <Enter> and then select Rebuild. Press <Enter> again.
Topology
HBA 0 : Marvell 0
Virtual Disks
VD 0: New_VD
PD 8: WDC WD800JD-22L
Free Physical Disks
PD 0: WDC WD800JD-22L
Help
Rebuilding with selected physical disk on this array.
ENTER: Operation F10: Exit/Save ESC: Return
Step 2:
The selection bar will move to the new drive. Press the <Space> key to select it and then press <Enter>.
When prompted to confirm, press <Y> to begin the rebuild or <N> to cancel.
Topology
HBA 0 : Marvell 0
Virtual Disks
VD 0: New_VD
PD 8: WDC WD800JD-22L
Free Physical Disks
*
PD 0: WDC WD800JD-22L
Help
Use space bar to select the free disks to be used in the array.
ENTER: Operation SPACE: Select F10: Exit/Save ESC: Return
Appendix
Marvell BIOS Setup (c) 2009 Marvell Technology Group Ltd.
ID
Name
Status
Stripe Size
[Delete]
RAID Mode
[Rebuild]
Size
BGA Status
Number of PDs
Numbers
Marvell BIOS Setup (c) 2009 Marvell Technology Group Ltd.
ID
Name
Status
Stripe Size
RAID Mode
Size
BGA Status
Rebuild
Number of PDs
Numbers
Do you want to rebuild with selected physical disk on this vd?
Yes
Information
:
:
:
:
:
:
:
:
:
Information
:
:
:
:
:
:
:
:
:
No
- 102 -
0
New_VD
Degrade
64K
RAID1
75776MB
N/A
1
8
0
New_VD
Degrade
64K
RAID1
75776MB
N/A
1
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents