14.5.3 Setting the Interface Standard
How to set up the Interface standard
1. From the Serial Communication menu, select the INTERFACE STANDARD item. (menu 14-20)
Interface standard, between brackets, is active and can be changed.
2. Use ENTER button or selection Wheel as toggle switch to enter the required interface standard RS232 or RS422.
If the Interface standard RS422 has been chosen, then, the item RS422 TERMINATION has to be set too.
3. From the Serial Communication menu, select the RS422 TERMINATION item. (menu 14-21)
Note: RS422 Termination: in case more ACSAR units are chained, then, the last one in the chain has to be terminated.
RS422 Termination status, between brackets, is active and can be changed.
4. Use ENTER button or selection Wheel as toggle switch to enter the RS422 Termination status to ON or OFF.
If the Interface standard RS422 has been chosen, then, the item RS422 TERMINATION has to be set too.
SERIAL COMMUNICATION
ACSAR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
0HQX 

14.6 Display BARCO Logo

About BARCO logo
The BARCO logon, in a black background window, can be pasted in the image. The place on the image is adjustable.
R5976519 ACSAR 12122002
SERIAL COMMUNICATION
ACSAR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
0HQX 
14. ACSAR Set Ups
71

Advertisement