Rec C Current Adjustment (Vc-215 Board) - Sony CCD TRV16 - Hi8 Handycam Camcorder Service Manual

8 video camera recorder hi 8 video camera recorder
Table of Contents

Advertisement

11. REC C Current Adjustment (VC-215 board)

Set the recording current levels of the REC Chroma signal. If it is
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noises will increase and white modulation noises
will be produced.
Mode
VTR recording (SP mode)
Signal
No signal
Pin !º of CN910 (REC RF)
Measurement Point
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
65
Specified Value
Hi8 model :
Standard8 model :
Note 1: Hi8 model: CCD- TR516/TR516PK/TR716
CCD- TRV36/TRV36PK/TRV43/TRV46/
TRV46PK
Standard8 model: CCD-TR315/TR416/TR416PK
Connection:
1) Remove C085 (0.01µF, Pin !§ of IC202).
Note: After completing "REC L Level Adjustment" and "REC C
Current Adjustment", replace C085 with new parts (1-162-
970-11 CERAMIC CHIP 0.01µF 10% 25V).
2) Connect Pin 1 of IC001 and GND with a 0.01F capacitor.
0.01µF capacitor: 1-101-004-00
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to "1". (Refer to "3. Bit value discrimination"
of "3-1-8. Service mode").
3) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to "0".
4) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin 6 of CN935 of DD-117 board
and GND with 4.7kΩ registor for a second.)
4.7kΩ registor : 1-249-425-11
5) Insert a tape, set to recording mode.
6) Select page: 0, address: 01, and set data: 01.
7) Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
8) Select page: 2, address: 61, and set data: 30.
9) Select page: F, address: 65, change the data and set the REC
chroma signal level (A) to the specified value.
10) Press the PAUSE button of the adjusting remote commander.
11) Select page: 2, address: 61, and set data: 10.
12) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
13) Select page: 0, address: 01, and set data: 00.
A = 34.6±1.2mV
A = 30.0±1.1mV
CCD-TRV16/TRV16PK
14) Select page: 0, address: 01, and set data: 01.
15) Select page: D, address: 14, and set the data memorized at step
2) of "Preparations only for the model without REC switch".
16) Press the PAUSE button of the adjusting remote commander.
17) Select page: D, address: 15, and set the data memorized.
18) Press the PAUSE button of the adjusting remote commander.
19) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-16.
Center of the luminance line width
A
1.35 µ sec

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents