Temp Indicator - Panasonic PT-DW530E Operating Instructions Manual

Dlp based projector
Hide thumbs Also See for PT-DW530E:
Table of Contents

Advertisement

TEMP indicator

J
Lamp
Information
indication
Warm-up status
Lighting in red
High temperature
inside. (WARNING)
High temperature
Blinking in red
inside.
(once)
(Standby condition)
High temperature
Blinking in red
inside.
(twice)
(Power ON condition)
Blinking in red
Cooling fan has
(3 times)
been stopped.
Note
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
z
Check point
Did you turn on the power when
z
the ambient temperature was
lower than approx. 0 °C (32 °F)?
Check the ventilation port is
z
blocked.
Is the room air temperature too
z
high?
Is the filter indicator lighted?
z
Monitor Lamp indicators
Remedial measure
Wait about 5 minutes in the current
z
status.
Install the unit in a location having
z
an ambient temperature from 0 °C
(32 °F) - 45 °C (113 °F).
Remove the object that is blocking
z
the ventilation port.
Move the projector to a temperature
z
of 0 °C (32 °F) - 45 °C (113 °F) and
the humidity of 20 % to 80 % (no
condensation).
Turn off the MAIN POWER switch
z
using the procedure on page 34 and
replace the ACF unit.
Turn off the MAIN POWER switch
z
using the procedure on page 34 and
consult the dealer.
77
ENGLISH -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-dx500ePt-dz570e