Maxtor QUICKVIEW 300 Product Manual page 22

80/100/120/160/200/250/300gb pata
Table of Contents

Advertisement

Installation
Master or Slave with the CS feature, the CS jumper is installed (1). The
drive's position on the 80 pin conductor Ultra ATA data cable then
determines whether the drive is a Master (Device 0) or a Slave (Device
1). If the drive is connected to the end of the Ultra (cable Select) data
cable the drive is a Master. If the drive is connected to the middle
connection it is set as a Slave.
Once you install the CS jumper, the drive is configured as a Master or
Slave by the state of the Cable Select signal: pin 28 of the PATA bus
connector. Please note that pin 28 is a vendor-specific pin that Maxtor
is using for a specific purpose. More than one function is allocated to
CS, according to the PATA CAM specification (see reference to this
specification in Chapter 1). If pin 28 is a 0 (grounded), the drive is
configured as a Master. If it is a 1 (high), the drive is configured as a
Slave. In order to configure two drives in a Master/Slave relationship
using the CS jumper, you need to use a cable that provides the proper
signal level at pin 28 of the PATA bus connector. This allows two drives
to operate in a Master/Slave relationship according to the drive cable
placement.
The Quickview 300 PATA hard disk drives are shipped from the factory
as a Master (Device 0 - CS jumper installed). To configure a drive as a
Slave (Device 1- DS scheme), the CS jumper must be removed. In this
configuration, the spare jumper removed from the CS position may be
stored on the PK jumper pins.
3.3.1.2
Drive Select (DS) Jumper
You can also daisy-chain two drives on the PATA bus interface by using
their Drive Select (DS) jumpers. To use the DS feature, the CS jumper
must not be installed.
To configure a drive as the Master (Device 0), a jumper must be installed
on the DS pins.
Note: The order in which drives are connected in a daisy chain
3.3.1.3
Master Jumper Configuration
In combination with the current DS or CS jumper settings, the Slave
Present (SP) jumper can be implemented if necessary as follows:
The CS position doubles as the Slave present on this drive.
• When the drive is configured as a Master
or CS jumper installed, and the Cable Select signal is set to
(0), adding an additional jumper (both jumpers DS and CS now
installed) will indicate to the drive that a Slave drive is
present. This Master with Slave Present jumper configuration
should be installed on the Master drive only if the Slave drive
does not use the Drive Active/Slave Present (DASP–) signal
to indicate its presence.
3-6
Quickview 300 80/100/120/160/200/250/300GB PATA
has no significance.
DS jumper installed
(

Advertisement

Table of Contents
loading

Table of Contents