Clearance Dimensions
Proximity to Side Cabinet Installation
Minimum Clearances from Adjacent
Combustible Construction
• The cooktop may be installed directly to
existing base cabinets.
• Above countertop 36" (91.4 cm) minimum
• The cooktop CANNOT be installed directly
• Side 8" (20.3 cm)
adjacent to sidewalls, tall cabinets, tall
• Rear 2-1/2" (6.4 cm) min.
appliances, or other side vertical surfaces
• Within 6" side clearance. Wall cabinets no
above 36" (91.4 cm) high. There must be a
minimum of 8" (20.3 cm) side clearance from
• Must be minimum 18" (45.7 cm) above
the cooktop to such combustible surfaces
above the 36" (91.4 cm) counter height.
• Wall cabinets directly above the product must be
• Within the 8" (20.3 cm) side clearance to
combustible vertical surfaces above
36" (91.4 cm), the maximum wall cabinet
depth must be 13" (33.0 cm) and wall cabinets
within this 8" (20.3 cm) side clearance must be
18" (45.7 cm) above the 36" (91.4 cm) high
countertop.
• Wall cabinet above the cooktop must
be a minimum of 36" (91.4 cm) above the
countertop for a full width of the cooktop.
This minimum height requirement does not
apply if a rangehood is installed over the
cooking surface.
• A 120 volt wall receptacle should be
located approximately 6" (15.2 cm) below
the countertop cutout and 12" (30.5 cm)
from the right side of the cutout.
i n .
" m
3 6
c m
. 4
9 1
(
Note: Dimensions shown are for use with combustible surfaces
unless otherwise stated.
10
(Proximity to Cabinets)
deeper than 13" (33.0 cm)
countertop
minimum 36" (91.4 cm) above the countertop
.
a x
" m
)
c m
1 3
. 0
3 3
(
i n .
" m
)
i n .
3 6
c m
. 4
" m
( 9 1
)
1 8
c m
. 7
( 4 5
)
Clearance Dimensions
The bottom of a standard hood should be
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66" (167.6 cm) to 72" (182.9 cm) above the
floor. Refer to the rangehood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.
6 6
" m
( 1 6
i n .
7 . 6
c m
t o
7 2
" m
( 1 8
a x
2 . 9
c m
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
6 6
"
" m
3 0
( 1 6
)
i n .
c m
3 0
7 . 6
. 2
" m
c m
( 7 6
( 7 6
i n .
7 2
t o
)
. 2
" m
c m
( 1 8
a x
t o
)
3 6
2 . 9
.
" m
6 "
c m
( 9 1
m )
a x
)
. 4
.
. 2 c
c m
( 1 5
)
Island Installation
11
(Wood/Composite Overlay)
W o
o d
/ C o
m p
O v
o s i
e r l
t e
a y
"
2 4
)
c m
. 0
( 6 1
o r
)
"
3 0
2 7
)
c m
" m
( 7 6
. 6
i n .
.
( 3 8
. 2
c m
)
t o
)
3 6
" m
( 9 1
a x
. 4
.
c m
)
Wall Installation

Advertisement

Table of Contents
loading

Table of Contents