Download Print this page

Electrolux EKM 90310 X Instruction Booklet page 6

Electrolux cooker instructions booklet

Advertisement

min. 50 mm
min.100 mm
"0" mm
Location
Your cooker is heavy, so be careful when moving or positioning it.
Do not try to move the cooker by pulling on the doors, handles or
control panel. The cooker is designed to "slot in" between 600mm
deep cabinets, spaced approximately 1000mm apart. It can also be
used free-standing, with a cabinet to one side, in a corner setting or
with its back to a wall.
In case of installation between kitchen units, their sides must withstand
a temperature of at least 90 degrees C.
The wall behind the cooker and 450mm above and across the width
of the cooker, should be an incombustible material or easy clean
895
895
surface such as ceramic tiles.
Any overhanging surface or cooker hood should be at least 650mm
(30") above the cooker hob. We do not recommend positioning the
cooker below wall cupboards, as the heat and steam from the cooker
may cause damage to the cupboard and its contents.
The cooker may be located in a kitchen, or a bed-sitting room, but
not in a room containing a bath or shower. The cooker must not be
installed in a bed-sitting room of less than 20m 3 .
LPG Models must not be installed in a room or internal space below
ground level, e.g. in a basement.
The cooker is fitted with 4 legs for
adjacent
furniture. To assemble legs,
four legs into the suitable threadings
underside
of the appliance ( fig 8).
Fig.
Fig. 9
CONNECTION
This appliance shall be installed in accordance whit the regulations
in force and only in a well-ventilated space. Read the instructions
before installing or using this appliance.
IMPORTANT
This cooker is supplied for use on gas specified on the data plate of
the appliance and cannot be used for any other gas without modification.
Conversion for use on other gases must only be undertaken by a
qualified person. For information for use on other gases contact your
local Service Centre.
min. 50 mm
"0" mm
easy adjustment of height to suit
lift
the cooker
up
and screw the
located at
the corners on the
OK
NO
8
GB
The cooker must be installed by a qualified person in accordance with
the Gas Safety (Installation and Use) (Amendment) Regulations 1990
and the relevant building/I.E.E. Regulations.
Failure to install the appliance correctly could invalidate any
manufacturers warranty and lead to prosecution under the above
quoted regulations.
Provision for Ventilation
The room containing the cooker should have an air supply in accordance
with BS 5440: Part 2: 1989. The room must have an opening windows
or equivalent; some rooms may also require a permanent vent. If the
room has a volume between 5 and 10m
2
50cm
effective area unless it has a door which opens directly to the
outside. If the room has a volume of less than 5m
2
air vent of 100cm
effective area. If there are other fuel burning
appliances in the same room, BS 5440: Part 2: 1989 should be
consulted to determine air vent requirements. Ensure that the room
containing the cooker is well ventilated, keep natural ventilation holes
or install a mechanical ventilation device (mechanical cooker hood).
Prolonged intensive use of the appliance may call for
additionalventilation, for example opening of a window, or more
effective ventilation, for example increasing the level of mechanical
ventilation where present. This cooker is not fitted with a device for
discharging the products of combustion. Ensure that the ventilation
rules and regulations are followed. Excess steam from the oven, vents
out at the top back edge of the cooker, so make sure that the walls
behind and near the cooker are resistant to heat, steam and
condensation. Your cooker must stand on a flat surface so that when
it is in position the hob is level. When in position check that the cooker
is level by using a spirit level and adjust the 2 feet at the rear and the
2 feet at the front if necessary. It is important that the cooker is stable
and level for the overall cooking performance.
Remember that the quantity of air necessary for combustion must
3
never be less than 2m
kW on the appliance data plate fig. 9
Gas Safety (Installation & Use) Regulations
It is the law that all gas appliances are installed by competent persons
in accordance with the current edition of the Installation & Use
Regulations. It is in your interest and that of safety to ensure
compliance with the law.
In the UK, CORGI registered installers work to safe standards of
practice.
The cooker must also be installed in accordance with BS 6172: 1990.
Failure to install the cooker correctly could invalidate the warranty
liability claims and could lead to prosecution.
Gas Connection
Prior to installation, ensure that the local distribution conditions (nature
of the gas and gas pressure) and the adjustment conditions are
compatible. The adjustment conditions for this appliance are stated
on the rating plate which can be found
appliance
drawer.
This appliance is not designed to be connected to a combustion
products evacuation device. Particular attention should be given to
the relevant requirements regarding ventilation.
Connection to the cooker should be made with an approved appliance
flexible connection to BS 669. Models for use with LPG should be
fitted with a hose suitable for LPG and capable of withstanding 50mbar
pressure. A length of 0.9 to 1.25m is recommended. The length of
hose chosen should be such that when the cooker is in situ, the hose
does not touch the floor.
The temperature rise of areas at the rear of the cooker that are likely
to come in contact with the flexible hose do not exceed 70
Gas pressure may be checked on a semi-rapid hob burner. Remove
the appropriate injector and attach a test nipple. Light the other burners
and observe that the gas pressure complies with the gas standards
in force.
Certain models can be set for sypply both on the right or lefthand
side. In this case it is sufficient to reverse the position of the cad nipple
reducer. At the end make sure than there is no leakage of gas.
INLET
6
3
, it will require an air vent of
3
, it will require an
/h for each kW of power (see total power in
).
*
on the inside of the front
STOP
0
C.

Advertisement

loading

This manual is also suitable for:

Ekm 90410 x