Settings in the Intelligent Provisioning Preferences screen are saved only after you exit the screen.
In the Perform Maintenance screen, if Insight Diagnostics is double-clicked, a message is displayed,
notifying you that you attempted to have two sessions of Insight Diagnostics open at the same
time.
Suggested action: When selecting menu options in the Perform Maintenance screen, only a single
click is necessary. To correct this situation, follow the instructions in the message.
User interface issues
The latest version of the online help was not incorporated into the Intelligent Provisioning firmware.
Some new features are not described and the help is not available in all languages.
Suggested action: For the latest information, see the Intelligent Provisioning User Guides on the
HP Intelligent Provisioning website.(http://www.hp.com/go/intelligentprovisioning)
When deploying a profile in the Deployment Settings screen, the Reset to Default Settings First
option does not reset the boot order.
Suggested action: None, this is working as designed.
When deploying a profile in the Deployment Settings screen, the Intelligent Provisioning language
is not being set as specified.
Suggested action: After the deployment is complete, access Intelligent Provisioning on the sever
and manually set the interface language.
Un-translated language content is displayed on Navigation buttons and in the Insight Diagnostics
screen.
Suggested action: None available.
AHS file logs can be created for an invalid date range.
Suggested action: Re-create the AHS log, using a valid date range.
The default System Profile displayed in the Hardware Settings screen does not match the profile
of the individual settings that were entered in the RBSU.
Suggested action: Expand the System Profile drop-down box and select the desired profile.
The System Profile displayed in the Review screen does not match the profile selected in the
Hardware Settings screen.
Suggested action: After the Intelligent Provisioning installation and configuration tasks for the
server completes, reboot the server and go to the Quick Configs screen. Confirm that the desired
system profile is displayed as the default. If needed, change the setting to the desired profile.
The System Profile displayed in the Quick Configs screen does not match the profile displayed in
the Hardware Settings screen.
Suggested action: Ensure that the desired system profile is displayed in the Quick Configs screen.
If needed, change the setting to the desired profile in the Quick Configs screen.
When updates are performed though the Firmware Update screen, NIC components might be
displayed twice.
Suggested action: None required.
The ACU component is installed during OS Installation. However, upon running HP SUM, HP
SUM discovery fails to determine that the ACU was installed.
Suggested action: Confirm that the ACU is already installed and that it is not still showing Ready
for installation.
6
Known issues and suggested actions