f
Remove the eight Torx T15 screws along the top and bottom edges of the
midplane (see Figure 63).
g
Pull the midplane forward to clear alignment pins and lift it up and out of
the disk system.
4
To replace the midplane:
a
Stand the new midplane inside the chassis and push it over the alignment
pins. Connectors automatically align with floating fan connectors inside
the chassis.
b
Insert and tighten eight screws into the midplane and chassis.
c
Replace the light pipes.
d
Replace the power switch extender arm.
5
Replace the top cover. See page 124.
6
Reseat and secure the LCCs (see page 117).
7
Reseat and secure the power supplies (see page 120).
8
Reinstall the disk modules.
Removal and Replacement 127