Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-TIMEOUT, 1
Critical
DIAG-XMIT, 1
32
Probable Cause
For portloopbacktest and
crossporttest:
Port failed to receive frame within
timeout period.
For centralmemorytest:
Port failed to detect an interrupt
within the timeout period.
This can be caused by a faulty cable
or deteriorated SFP. It can also
indicate deeper problems in the
motherboard or ASIC.
Port failed to transmit frame. This
usually indicates an ASIC failure.
This message is generated by the
camtest, portloopbacktest,
and spinsilk commands, if
problems are found.
Recommended Action
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes