Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-ERRSTAT (ENCOUT), 1
Critical
DIAG-ERRSTAT (TRUNC), 1
Critical
DIAG-INIT, 1
Critical
DIAG-INTNIL, 1
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes
Probable Cause
Port Error Statistics counter is
nonzero, meaning that an
Encoding error, outside
frame error was detected when
receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Port Error Statistics counter is
nonzero, meaning that a
Truncated frame error was
detected when receiving frames.
This can be caused by a faulty cable
or deteriorated SFP. It can also
indicate deeper problems in the or
ASIC. This message is generated by
the portloopbacktest or
spinsilk commands, if problems
are found.
Port failed to go active in the
loopback mode requested. This can
be caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the or ASIC.
This message is generated by the
crossporttest,
portloopbacktest, or
spinsilk commands, if problems
are found.
ASIC failed to get a CMI error
(interrupt). This usually indicates an
ASIC failure. This message is
generated by the cmitest
command, if problems are found.
Documentation Updates
Recommended Action
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.