94
SEC-1164
Recommended
Do not use lockdown option with the secModeEnable command when a switch is already in secure
Action
mode.
Severity
ERROR
SEC-1164
Message
<timestamp>, [SEC-1164], <sequence-number>,, ERROR, <system-name>, Lockdown
option cannot be applied on a non-FCS switch.
Probable Cause
Indicates the attempt to enable security is made on a switch that is not present in the fabric
configuration server (FCS) list.
Recommended
Add the switch to the FCS policy list when using the lockdown option to enable security.
Action
Severity
ERROR
SEC-1165
Message
<timestamp>, [SEC-1165], <sequence-number>,, ERROR, <system-name>, Low memory,
failed to enable security on all switches.
Probable Cause
Indicates the system is low on memory.
Recommended
Wait a few minutes and try the command again.
Action
Severity
ERROR
SEC-1166
Message
<timestamp>, [SEC-1166], <sequence-number>,, ERROR, <system-name>, Non FCS tries
to commit failover.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR