HP P6000 Installation Manual page 39

Enterprise virtual array
Hide thumbs Also See for P6000:
Table of Contents

Advertisement

Figure 24 iSCSI device folder properties
When discovery is complete, the iSCSI or iSCSI/FCoE modules will be listed under iSCSI Devices
(Figure 25 (page
39)). The modules are listed as iSCSI Controller 01 and iSCSI Controller 02.
Select a controller to display the iSCSI Controller Properties window. Select the Mgmt Port tab to
configure the telnet management port IP addresses to a common class subnet and to configure
other settings. The telnet management port can be configured using IPv4 and IPv6 addressing.
NOTE:
HP recommends setting static IP addresses in a common class subnet on the telnet
management ports for consistent connectivity and to support peer pairing for persistent reservations.
If an iSCSI controller pairing failure is displayed in HP P6000 Command View, use the following
CLI commands to help repair the issue and possibly avoid having to remove the controller and
rediscover the controller actions:
show peers
peer rm
peer add
IMPORTANT:
If either P6300/P6500 controller is down or halted, you cannot modify the existing
iSCSI or iSCSI/FCoE module LUN presentations in HP P6000 Command View.
Figure 25 iSCSI Controller Mgmt Port properties
The iSCSI modules are configured as one instantiated host—both Fibre Channel ports from each
iSCSI module (as illustrated in
(Figure 26 (page
40)). The Fibre Channel ports associated with each iSCSI host come from the
IEEE format 5 HP-registered MAC addresses and represent the WWNs of the FC ports of the iSCSI
Figure 21 (page
35)) and as iSCSI MPX hosts in the Hosts folder
HP P6000 Command View discovery
39