Interface Requirements; Fc-Al Features; Fibre Channel Link Service Frames - Seagate ST336807FC - Cheetah 36 GB Hard Drive User Manual

Cheetah 10k.7 fc product manual
Hide thumbs Also See for ST336807FC - Cheetah 36 GB Hard Drive:
Table of Contents

Advertisement

9.0

Interface requirements

This section partially describes the interface requirements as implemented on Cheetah 10K.7 FC drives. Addi-
tional information is provided in the Fibre Channel Interface Manual (part number 77767496).
9.1

FC-AL features

This section lists the Fibre Channel-specific features supported by Cheetah 10K.7 FC drives.
9.1.1

Fibre Channel link service frames

Table 15 lists the link services supported by Cheetah 10K.7 FC drives.
Table 15:
Link services supported
Type of frame
Basic link service frames
Basic link service reply frames
Extended link service frames
Extended link service reply frames
Fibre Channel Services
Cheetah 10K.7 FC Product Manual, Rev. D
Link service
Abort Sequence (ABTS)
Basic_Accept (BA_ACC)
Basic_Reject (BA_RJT)
N_Port Login (PLOGI)
Fabric Login (FLOGI)
Logout (LOGO)
Process Login (PRLI)
Process Logout (PRLO)
Read Link Status (RLS)
Fabric Address Notification (FAN)
Port Discovery (PDISC)
Address Discovery (ADISC)
Third-party Process Logout (TRPLO)
Accept (ACC)
Link Service Reject (LS_RJT)
Register FC-4 Types (RFT_ID)