Table 2-1 POST Error Codes and Messages List
NOTE:
To diagnose a problem, first find the BIOS error
messages or codes in left column. If directed to a
check procedure, replace the FRU indicated in the
check procedure. If no check procedure is indicated,
the first Action/FRU listed in right column is the most
likely cause.
BIOS Error Codes,
Messages
Memory Address Error at
.......
Memory Parity Error
at.............
Memory Size Has Changed
Since Last Boot
Memory Verify Error
at............
RAM Parity Error-Checking
For Segment..
Offending Address Not
Found
Offending Segment
Press A Key To Reboot
Should Be Empty But EISA
Board Found
Please Run EISA
Configuration Utility
Should Have EISA Board
But Not Found
Please Run EISA
Configuration Utility
Slot Not Empty
System Halted, (CTRL-ALT-
DEL) To Reboot.....
Wrong Board in Slot
Please Run EISA
Configuration Utility
42
IBM Desktop System HMM
Action/FRU
1. Insert the memory
modules in the DIMM
sockets properly, then
reboot the system
2. Memory module. See
"005 -" on page 65 to
replace memory module
3. System board
1. Enter Configuration/
Setup Utility and load the
default settings.
2. Remove all adapter cards
that are NOT factory-
installed, then reboot the
system.
3. System board
1. Message Only
1. No ESIA slot available
1. No ESIA slot available
1. No ESIA slot available
1. Message Only
1. No ESIA slot available