Temp Read Command; Lamp Mode Read Command - Sanyo PLC-HF15000L - 15000 Lumens Manual

Basic serial command functional specifications
Hide thumbs Also See for PLC-HF15000L - 15000 Lumens:
Table of Contents

Advertisement

PLC-HF15000L Basic Serial Command Functional Specifications
7.7

Temp Read Command

COMMAND
"CR6" [CR]
Get the temperature information inside projector
Detail
With more than one temperature sensors installed in the projector, it is possible
to get all temperatures at once.
Acceptable
Response
Unacceptable
7.8

Lamp Mode Read Command

COMMAND
"CR7" [CR]
Get current Lamp Mode in the multiple-lamp projector.
Detail
When there is any fail lamp, also can get the information about.
Acceptable
Response
Unacceptable
"%1ÿ ? %2" [CR]
%1 = temperature at Sensor 1
%2 = temperature at Sensor 2
Temperature data is expressed as "00.0".
When the temperature goes under 0, the first character is "-" like
"-05.5" [CR].
%10 %2
When no temperature data returns due to hardware problems
the first character is "E" like" E00.0" [CR].
With more than one temperature sensors installed, the projector
returns the values in series.
Ex) "_31.5_ _35.2" [CR]
Each sensor data follows in sequence with one space between
each of them.
"?" [CR]
"%1" [CR]
ex: "0F"[CR]
The first digit indicates Lamp Mode.
0 = 4-lamps Mode
1 = 2-lamps Mode (Lamp No.1 and No.4 used)
2 = 2-lamps Mode (Lamp No.2 and No.3 used)
3 = 3-lamps Mode (Lamp No.1, No.2 and No.3 used)
4 = 3-lamps Mode (Lamp No.1, No.2 and No.4 used)
5 = 3-lamps Mode (Lamp No.1, No.3 and No.4 used)
6 = 3-lamps Mode (Lamp No.2, No.3 and No.4 used)
The second digit indicates if the lamp is ON or OFF.
Data is shown as "0-9" and "A-F", which is described in 4-bit
data. Assign each bit for each lamp data.
ex: 0 = All lamps are OFF
%1
1 = No.1 is ON, the others are OFF
2 = No.2 is ON, the others are OFF
4 = No.3 is ON, the others are OFF
8 = No.4 is ON, the others are OFF
3 = No.1 and No.2 are ON, the others are OFF
5 = No.1 and No.3 are ON, the others are OFF
9 = No.1 and No.4 are ON, the others are OFF
6 = No.2 and No.3 are ON, the others are OFF
A = No.2 and No.4 are ON, the others are OFF
C = No.3 and No.4 are ON, the others are OFF
7 = No.1, No.2 and No.3 are ON, the other is OFF
B = No.1, No.2 and No.4 are ON, the other is OFF
D = No.1, No.3 and No.4 are ON, the other is OFF
E = No.2, No.3 and No.4 are ON, the other is OFF
F = All lamps are ON
"?" [CR]
20/23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-hf15000l