Name
Output Voltage(V) Output Current (mA)
LRTC
2.0
LD1
1.2/1.5
LIO
1.8/2.85
LRFXO
2.5
LMEM
2.5
LANA
2.5
LSIM
1.8/2.85
LBUF
2.6/2.8/3.0/3.2
LRFRX
2.5
LRFTRX
1.5
LDO output voltage selection
• LD1, LIO, LSIM, LBUF output voltage programmable by software.
• LMEM output voltage is selectable by pin configuration upon startup.
Active and idle power saving options:
• The flexible clock switching options allow minimizing the power consumption during the operation
phases of the E-GOLDvoice.
• Current consumption during the standby mode is minimized by reducing the clock to 32 kHz and
switching it off for most of the device. In addition, the power supply for the TEAKLite ROM is
switched off and the controller RAM is switched to a power saving mode.
Start-up and Reset Control State Machine Features
• Power up upon battery insertion, push button, alarm, charger connection.
• Detection of battery exchange or re-insertion.
• Complete start-up sequence management.
• System turn-on, system turn-off operation management including emergency (under-voltage) and
programmed shutdown functions.
• Internal reset of the baseband, including silent reset.
• Tri-state function of the baseband module.
• Standby mode controlled by VCXO_EN provided by SCCU module.
Comment
4
Used for the real time and digital PMU supply
150
Used for the core supplies (MCU and DSP via switch)
30
Used for the I/O pad supply and, for example, the display
10
Used for the crystal oscillator supply
100
Used for the external memory supply, voltage can be
configured during startup
100
Used for analog (audio and baseband processing) and
headset driver
30
Used of the SIM card supply
300
Used for the loudspeaker and earpiece driver
100
Used for the RF RX part
120
Used for the RF TX/TX part
Figure 3-14-2 EGold Voice PMU