Rj45 Response Table; Rs232 Command Table - ViewSonic PJD6245 User Manual

Hide thumbs Also See for PJD6245:
Table of Contents

Advertisement

RJ45 response table

Status
Normal => ACK
Write
Incorrect => ERROR ACK
Timeout (>100ms)
Status
BYTE0 BYTE1 BYTE2 BYTE3 BYTE4 BYTE5 BYTE6 BYTE7~N
0x05
0x14
Ex1. Read power status: 0x05 0x14 0x00 0x03
Read
Ex2. Read brightness: 0x05 0x14 0x00 0x04 0x00 0x00
Ex3. Read lamp hours: 0x05 0x14 0x00 0x06
0x00 0x00 0x42
The RJ45 commands can only be received via TCP port 4661.
Please refer to the below RS232 command table for the commands.

RS232 command table

<Pin assignment for this two end>
Pin
1
3
5
7
9
<Interface>
Baud Rate
Data Length
Parity Check
Stop Bit
Flow Control
<RS232/RJ45 command table>
Function
Status
Power
Reset
Reset Color
Settings
Response
Response Code
0x00
LSB
MSB
Description
Pin
NC
2
TX
4
GND
6
RTSZ
8
NC
RS-232 protocol
Action
Turn on
Write
Turn off
Power status
Read
0x07 0x14 0x00 0x05 0x00 0x34 0x00 0x00 0x11 0x00 0x5E
(on/off)
Execute
Execute
74
Response Code
0x03 0x14 0x00 0x00 0x00 0x14
0x00 0x14 0x00 0x00 0x00 0x14
0x00
0x00
0x00 0x00 0x00 0x01 0x18
0x00 0x32 0x00 0x4A
0x00 0x00 0x00 0x28 0x00
Description
RX
NC
NC
CTSZ
115200 bps (default)
8 bit
None
1 bit
None
cmd
0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x00 0x00 0x5D
0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x01 0x00 0x5E
0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x02 0x00 0x5F
0x06 0x14 0x00 0x04 0x00 0x34 0x11 0x2A 0x00 0x87
N/A
BYTE N+1
Data
Checksum
= On
= 50
= 40