Using the RS-232C Serial Interface

This section describes how to use the RS-232C serial interface.
How to Connect the RS-232C Serial Interface
Use Lexmark serial cable P/N 1038693 (15.24 m or 50 ft) to connect the serial
interface.
RS-232C Serial Cable Pin Assignments
The RS-232C serial cable appears as follows:
Table 8-3: Dedicated Serial Connector Pin Assignments (RS-232C)
Pin
1
2
3
4
5
6
25-Pin
D-Shell
13
25
(Male)
1
14
Printer
Side
Signal
Direction
Description
GND
Frame Ground
TXD
Out
Transmit Data. The pin transmits data to your computer or
terminal.
RXD
In
Receive Data. The pin receives data from your computer or
terminal.
RTS
Out
Request to Send. The printer sets this signal high and the
signal remains high while the printer is on.
CTS
In
Clear to Send. This pin is optionally used for serial data flow
control protocol when in serial mode.
DSR
In
Data Set Ready. This pin is optionally used for data
validation, depending on the Honor DSR setting, or flow
control, depending on the Serial Protocol setting.
8-21
Interfaces
25-Pin
D-Shell
13
25
(Female)
1
14
Computer
Side