Maintenance indicator
Normal
Temperature
Off
warning
indicator
Lamp
Green on
indicator
(Green
blinks
when the
lamp is
warming
up.)
Power
Green on/
indicator
Red on
Green
blinks
(Cooling)
Info
• If the temperature warning indicator illuminates, and the projector enters Standby mode, follow the
possible solutions above and then wait until the projector has cooled down completely before
plugging in the power cord and turning the power back on. (At least 10 minutes.)
• If the power is turned off for a brief moment due to power outage or some other cause while using
the projector, and the power supply recovers immediately after that, the lamp indicator will illuminate
in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace
the power cord in the AC outlet and then turn the power on again.
• The cooling fan keeps the internal temperature of the projector constant and this function is
controlled automatically. The sound of the cooling fan may change during operation because the fan
speed may change and this is not a malfunction.
62
Problem
Abnormal
Red blinks
The internal
(On)/
temperature is
Red on
abnormally high.
(Standby)
Red on
The lamp does
not illuminate.
Time to change
the lamp.
Red on
The lamp does
(Standby)
not illuminate.
Red blinks The power
indicator blinks in
red when the
projector is on.
Cause
• Temperatures
around the projector
are high.
• Blocked air intake
• Cooling fan
breakdown
• Internal circuit failure
• Clogged air intake
• The lamp is shut
down abnormally.
• Remaining lamp life
becomes 5% or less.
• Burnt­out lamp
• Lamp circuit failure
• The lamp unit cover
is open.
Possible Solution
• Use the projector in an
area with a temperature of
lower than 95°F (+35ºC).
• Relocate the projector to
an area with proper
ventilation. (See page 8.)
• Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 71) for
repair.
• Disconnect the power cord
from the AC outlet, and
then connect it again.
• Carefully replace the lamp.
(See page 63.)
• Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 71) for
repair.
• Please exercise care when
replacing the lamp.
• Securely install the cover.
• If the power indicator blinks
in red even when the lamp
unit cover are securely
installed, contact your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 71) for
advice.