Sensor
Sensor
The Converting Formula
Number
Name
Upper non-
recoverable
Actual_Reading (℃) = Raw_Data
CPU1_
61h
Temp
0x4E
Actual_Reading (℃) = Raw_Data
CPU2_
62h
Temp
0x4E
Actual_Reading (℃) = Raw_Data
CPU3_
63h
Temp
0x4E
Actual_Reading (℃) = Raw_Data
CPU4_
64h
Temp
0x4E
Actual_Reading (degrees C) = Raw_Data (only support Sensor
FCB
Reading, threshold unsupport)
2Ah
Ambien
t1
0xFF
DIMM_
Actual_Reading (℃) = Raw_Data
A1 to
E0h-FFh
0x63
DIMM_
D8
Power Supply
MB_12
Actual_Reading = Raw_Data
A1h
V_Curr
0xFF
ent
Actual_Reading = Raw_Data
PSU 1
A3h
POUT
0xFF
Actual_Reading = Raw_Data
PSU 2
A4h
POUT
0xFF
Upper
Upper
Lower non-
critical
non-
recoverable
critical
0x4C
0x4B
0x00
0x4C
0x4B
0x00
0x4C
0x4B
0x00
0x4C
0x4B
0x00
0x32
0x00
0x00
0x61
0x5F
0x00
0xFF
0xFF
0x00
0xFF
0xFF
0x00
0xFF
0xFF
0x00
Sensors Threshold
Lower
Lower
critical
non-
critical
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
 
|