Download Print this page

Bushnell 70-0001 Instruction Manual page 5

Digital compass

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Temperature Alarm
Sets the alarm to sound when the temperature measurement reaches
the programmed level. In the Alarm Mode, the Temperature alarm
uses the same measurement units (ºC or F) that were last set in the
Temperature Mode. To change this you must first change the
temperature units in the Temperature Mode. Using the UP/DOWN
once changes the temperature in tenths of a degree. Holding the
button down changes the temperature in increments of 1 degree.
Beep Function
In the Alarm mode a Beep function is also available. When activated,
the beep function causes a beep sound to be made whenever a
button is depressed, even when the Alarm function is turned off. To
activate the function go to the Beep function in the Alarm Mode,
press the COMP button and 'ON' is displayed. Press again and
'OFF' is displayed.
Stopwatch Mode
Press MODE button until Stop Watch Mode is displayed. To
operate, press UP button to start and press again to stop. Pressing
DOWN button will reset the Stop Watch.
For split timing function, press the DOWN button while the Stop
Watch is operating in order to stop the display and press again to
continue. You can also press the DOWN button while the Stop
Watch is operating to stop the display and then press the UP button
to stop the Stop Watch and display the final reading. Press the
DOWN button again to reset the Stop Watch.
Stop Watch Mode / Split Timing Function
Split timing function is displayed as 'SPL' when activated and the
display returns to normal when DOWN button is pressed.
6
C
T
A
OUNTDOWN
IMER
LARM
Countdown / Reverse-Timer Mode
Press MODE button until Countdown Timer Mode is displayed,
represented by 'RT' (reverse timer). To operate press UP button to
start and press again to stop, then press DOWN button to reset the
Countdown Timer.
To set the Countdown Timer press and hold down ADJ button for
3 seconds, which will cause the seconds setting to blink. Adjust with
the UP or DOWN button, and then press MODE button to adjust
next setting. Press ADJ button to save settings and exit. Press
COMP for 'AUTO' to allow Countdown Timer to repeat function
automatically, and press COMP again to turn off 'AUTO' function.
Press any button when alarm sounds to stop the Countdown Timer.
If nothing is pressed the Countdown Timer will stop beeping after
10 seconds, but it will continue if the 'AUTO' function is set on. To
stop the Countdown Timer if the 'Auto' function is on, you must go
to the Countdown Timer Mode and press COMP to turn off the
'Auto' function and then press UP button to stop it.
D
C
IGITAL
OMPASS
Compass Mode
Press MODE button until Time Mode is displayed, and then press
COMP button. If already in Time Mode, simply press COMP
button and Compass Mode is displayed. Hold the compass level
using the bubble level to get a reading. If the Cardinal Points blink
then the compass probably needs to be calibrated. (See trouble
shooting tips.)
Compass Calibration
In Compass Mode, hold down ADJ button for 3 seconds.
Calibration Mode is displayed. Put the compass on a level, non-
magnetic surface and press the COMP button. The word CAL will
start blinking.
Then, rotate the compass 2 full circles slowly
WHILE HOLDING THE COMPASS LEVEL. When done, press
COMP again. When completed, the display shows 'DONE' and it
7

Hide quick links:

Advertisement

loading