KC, GF, JA, JB, MK & MY Series Video Systems
The KCW-D/B adaptor converts the 2-wire video signal from the KC, GF, JA, JB, MK & MY systems to a
standard composite video output signal. This allows the image from the door station to be seen on a
standard CCTV monitor or TV (video input). The video image can also be recorded if connected into a VCR,
DVR, or other recording device.
WIRING DIAGRAM: KCW-D/B for Composite Video Output from a KC monitor
KC-DAR
A1
A2
PS-2420UL
KC-DAR Video Door Station with Stand-alone Monitor (No audio communication or Tilt capabilities)
IMPORTANT:
CN3 speaker microphone connector
KC-DAR
inside KC-DAR must be unplugged to
prevent the possibility of feedback.
A1
A2
Auxiliary Light
To Aux Light Power Supply
TO POWER THE CAMERA:
(1) WHEN IN USE
- Install a switch or relay contact in series with the "+" terminal from the power supply (see diagram).
- Solder a jumper between points labeled AA & BB on the KCW-D/B main PC board (see illustration).
This allows the camera to be activated manually, or when relay contact is activated.
(2) CONTINUALLY
- Solder a jumper between points labeled AA & BB on the KCW-D/B main PC board (see illustration).
This will provide continuous power to the camera, which may cause the camera to be warm.
Note: Continually powered, the overall life of the camera will be reduced and condensation may occur.
Video Demodulator for the
- INSTRUCTIONS -
KC-1GRD/
KC-1HRD
1A1
1A2
+
+
-
-
RY-PA
NOTE:
Relay will activate and auxiliary
light will illuminate while the JB
camera is active.
Switch
PS-2420UL
(not supplied by Aiphone)
+
-
KCW-D/B
DA1
Composite
DA2
video output
b
E
DV+
DV-
Center to DV+
Braid to DV-
+
-
KCW-D/B TERMINAL DEFINITIONS:
KCW-D/B
DA1/DA2 2-Wire input from KC-DAR
DV+
Coax output: Center conductor
DA1
DV-
Coax output: Braided shield
DA2
b
Pos. 10V Output for Relay
E
Neg. 10V Output for Relay
+
Positive 24V DC w/Switch
b
-
Negative
E
DV+
To standard monitor
DV-
or monitor input on a
video switcher.
Solder jumper wire between
two holes in land pattern.
+
(JP101 A-to-A; JP102 B-to-B
-
Component side view)
KCW-D/B TERMINAL DEFINITIONS:
DA1/DA2 2-Wire input from KC monitor
DV+
Coax output: Center conductor
DV-
Coax output: Braided shield
b
Not functional
E
Not functional
+
Positive 24V DC
-
Negative
Output Signal:
75 ohm, 1V peak-to-peak.
Coax: Solid copper core with copper braid.
Standard CCTV
Monitor
Center to DV+
Braid to DV-
Pg. 1