Aiphone RY-IP44 Programming Manual

Input/output network adaptor for ix series
Hide thumbs Also See for RY-IP44:

Advertisement

Quick Links

Note: IX Mobile should be included at the start of the creation of a new IX
Series system, rather than added after the system as been configured.
Refer to pages 9-11 of this manual for a walk-through of this process.
ATTENTION:
This manual is for programming the RY-IP44 with the IX Series system only. Refer to the IX Series
Installation and Setting Manuals for complete installation/programming information.
For instructions featuring the RY-IP44 with the IS IP Series, visit www.aiphone.com/ISIP-RYIP44
For instructions featuring the RY-IP44 with the IPW-1A, visit www.aiphone.com/IPW1A-RYIP44
RY-IP44
Input/Output Network Adaptor
Programming Manual
For use with IX Series
0319

Advertisement

loading

Summary of Contents for Aiphone RY-IP44

  • Page 1 Refer to pages 9-11 of this manual for a walk-through of this process. ATTENTION: This manual is for programming the RY-IP44 with the IX Series system only. Refer to the IX Series Installation and Setting Manuals for complete installation/programming information.
  • Page 2: Package Contents

    When using the RY-IP44 only as a Mobile App Server for IX Mobile, begin on page 6 as SIF and CGI are not used in this instance.
  • Page 3 The intercom system should be fully programmed and operational prior to programming for the RY-IP44 adaptor integration. IX Series stations use SIF events to interact with and trigger the contact outputs of the RY-IP44, and CGI is used when the RY-IP44 interacts with a station using the contact inputs.
  • Page 4 Creating a simple line of code, in the form of a .ini file, is required to allow an IX Series 1 (IX-DA, IX-BA, IX-MV) device to communicate to the RY-IP44. The example below is shown using a common text editor (i.e. Notepad), and saving it with an .ini extension.
  • Page 5 You will be asked if you want to continue. Click OK. Confirm Success/Failed in the Status Step 2 Column. Check the box beside each station that was modified, then click Settings under “Select file type to be uploaded” 5 | RY-IP44 with IX Programming Manual...
  • Page 6 Configuring the RY-IP44 Using a web browser, access the RY-IP44 using its default IP address of 192.168.1.45. The landing page will be the Device Status screen. Configuration button Digital input status Relay status and control. Click on each LED to verify relay function.
  • Page 7 • Active during Calling and Communicating When the relay action is set for one of the “Door Release” options, the relay on the RY-IP44 will trigger when the associated station’s door release contact is triggered. When the relay action is set for any of the “Active While” options, the relay will trigger when the associated station calls or communicates at any priority level.
  • Page 8 IX Series: Input Programming Note: The RY-IP44 inputs can have different calling rules than the default calling rule set for a station during the IX Series programming. • Select the call-in priority level for each input using the Priority drop down menu.
  • Page 9 The IP Address assigned to each station can also be changed from what Support Tool automatically assigned. When done making changes, click OK. 9 | RY-IP44 with IX Programming Manual...
  • Page 10 If all stations show Success, click Next. Step 5.6 A warning will appear letting you know that some stations have not been associated. This is because Mobile can not be associated this way. Click OK to continue. 10 | RY-IP44 with IX Programming Manual...
  • Page 11 The Setting File must be exported in order to obtain the configuration file required to set up the IX Mobile devices. Click File > IX Support Tool Export System Configuration then follow the steps above. 11 | RY-IP44 with IX Programming Manual...
  • Page 12: Configuration File

    Locate the configuration file with the same number that was assigned to the mobile station in IX Support Tool. Copy the configuration file to a location on the programming PC that can easily be transferred to the mobile device. Configuration File Example: 12 | RY-IP44 with IX Programming Manual...
  • Page 13 Default ID: admin Default Password: admin Tap App Server. Enter the IP Address and Port Number for the App Server (RY-IP44). Refer to page 11 for information on setting up the App Server. Tap Import from File. Select the configuration file that was transferred to this device in Step 3.
  • Page 14 Default ID: admin Default Password: admin Tap App Server. Enter the IP Address and Port Number for the App Server (RY-IP44). Refer to page11 for information on setting up the App Server. Tap Import from File. Select the configuration file that was transferred to this device in Step 5.
  • Page 15 RY-IP44 Dimensions Mounting: The RY-IP44 adaptor mounts to an Aiphone Depth: W-DIN11 mounting rail (sold separately). 1-1/4” 4-1/8” RY-IP44 Wiring Power Transformer (use proper power for the strike, mag lock, or external signaling device being used). Relay contact rating: 30V DC, 0.5A.