Electrical Connection - Bosch WTVC533CUS Operating Manual

Vision 300/500/800 series electric clothes dryers
Table of Contents

Advertisement

Available languages

Available languages

6. Attach the "Y" adapter to the short
hose. Tighten the coupling (by
hand) until it is firmly seated on the
hose.
I-_1 Do not use pliers to tighten plastic
threaded fittings onto plastic or
metal threaded connections.
7. Attach the washer cold water
supply hose to the "Y" connector.
Hand tighten only.
8. Attach the dryer water supply hose
to the other coupling of the "Y"
connector.
Hand tighten only.
9. Tighten only metal-to-metal
couplings on the "Y" connector
and short hose an additional
two-thirds turn using pliers.
I-_1 Do not overtighten. Damage to
the coupling could result.
10. Attach the right-angle connector
on the water supply hose to the
inlet valve located at the top left of
the dryer.
I-_1 Check to see that the rubber
washer does not fall out, and is
properly seated in the right-angle
connector.
11. Hand tighten the coupling until it
is seated on the connector. Do
not use pliers, hand tighten only.
I-_1 Do not overtighten. Damage to
the coupling could result.
12. Turn on the water faucet.
13. Check for leaks around the "Y"
connector, faucet and all hoses.
Electrical
Connection
Power cord must be connected
by a qualified technician
or a
licensed electrician
only.
Connect
to individual branch
circuit.
Do not use an adapter.
Do not use an extension
cord.
Do not remove ground prong.
Your dryer comes without a power
supply cord. The power cord must
meet the following requirements:
-
UL listed in the USA
-
240 volt rated (minimum)
-
30 amps
-
Type SRDT or DRT and marked for
use with clothes dryers
-
Five feet long (minimum)
Power cord must be connected
or a
by a qualified technician
licensed electrician
only.
Use only a U.L. approved
30 amp power cord with strain
relief clamp -
note manufacturer's
instructions.
Do not reuse old power cord.
Cord must have closed loop or
upturned
end wire terminating
connectors.
Do not make a sharp bend or
crimp wiring/conductor
at
connections.
Only a 4-conductor
cord shall
be used when the appliance
is
installed in a mobile home, in a
recreational
vehicle, in a new
branch circuit installation
or an
area where the local codes do
not permit grounding
through
the neutral.
Additional
grounding
procedure
Some local regulations may
require a separate ground. In such
cases, the required accessory
ground wire, clamp and screw
must be purchased separately.
Contact your local dealer or
customer service for additional
details (see page 32).
-
Never ground the dryer to plastic
plumbing lines, gas lines or water
pipes.
Grounding
instruction
This appliance must be grounded. In
the event of a malfunction or
breakdown, grounding will reduce the
risk of electric shock by providing a
path of least resistance for the electric
current.
14

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents